background image

SPECIFICATIONS—FLOOR STANDING HEATED & AMBIENT MODELS 

Model Volts 

Amps 

Hz 

Phase 

Plug 

PUCA-24S 120 

60 

Single 

NEMA 

5-15P 

PUCA-24S-PT 120 

60 

Single 

NEMA 

5-15P 

PUCA-14SAO 120 

0.75 

60 

Single 

NEMA 

5-15P 

PUCA-14SAO-PT 120 

0.75 

60 

Single 

NEMA 

5-15P 

PUCA-24SAO 120 

60 

Single 

NEMA 

5-15P 

PUCA-24SAO-PT 120 1  60 

Single 

NEMA 

5-15P 

Electrical Characteristics-Ambient Cabinets 

Model Volts 

Amps 

Hz 

Phase 

Plug 

PUCH-24S 120 

16 

60 

Single 

NEMA 

5-20P 

PUCH-24S-PT 120 

16 

60 

Single 

NEMA 

5-20P 

PUCH-14SAO 120 

60 

Single 

NEMA 

5-15P 

PUCH-14SAO-PT 120 8  60 

Single 

NEMA 

5-15P 

PUCH-24SAO 120 

16 

60 

Single 

NEMA 

5-20P 

PUCH-24SAO-PT 120 16 60 

Single 

NEMA 

5-20P 

Electrical Characteristics-Heated Cabinets 

European Ratings-Ambient Cabinets

 

Model Volts 

Amps 

Hz 

Plug 

 

Receptacle 

Plug  

Receptacle 

PUCA-24S-I 

230 

0.5 

60 

C, E, F, G 

C, E, F, G 

PUCA-24S-PTI 

230 

0.5 

60 

C, E, F, G 

C, E, F, G 

PUCA-14SAO-I 

230 

0.4 

60 

C, E, F, G 

C, E, F, G 

PUCA-14SAO-PTI 

230 

0.4 

60 

C, E, F, G 

C, E, F, G 

PUCA-24SAO-I 

230 

0.5 

60 

C, E, F, G 

C, E, F, G 

PUCA-24SAO-PTI 

230 

0.5 

60 

C, E, F, G 

C, E, F, G 

European Ratings-Heated Cabinets

 

Model Volts 

Amps 

Hz 

Plug 

 

Receptacle 

Plug  

Receptacle 

PUCH-24S-I 

230 

60 

C, E, F, G 

C, E, F, G 

PUCH-24S-PTI 

230 

60 

C, E, F, G 

C, E, F, G 

PUCH-14SAO-I 

230 

60 

C, E, F, G 

C, E, F, G 

PUCH-14SAO-PTI 

230 

60 

C, E, F, G 

C, E, F, G 

PUCH-24SAO-I 

230 

60 

C, E, F, G 

C, E, F, G 

PUCH-24SAO-PTI 

230 

60 

C, E, F, G 

C, E, F, G 

Carter-Hoffmann counter-top PUC Smart Order Pick Up cabinets are de-
signed for automated pick-up, carry-out and drop-off.  Add-on cabinets can be 
connected to Master cabinets for flexible capacity. Cabinets are connected via 
Ethernet or WI-FI to generate an order code for notification. They feature a 
capacitive touchscreen with scanner for order loading and pick-up. They can 
be stand-alone for manual order entry or can be integrated with POS software 
for seamless function, data collection and analytics. Software includes order 
management, customer notification and cleaning cycle notification.  Stainless 
steel construction with anti-microbial powder-coated exterior. Each locker is 
12”W x 14”H x 14”D (304 x 356 x 356 mm) with an automatic pop-latch door, 
manual close.    
 
Cabinets come in heated or ambient, counter-top or floor models, front-loaded 
or pass-through, master cabinet controls in center, on the left or on the right; 
doors have a polycarbonate viewing window.  

Model 

Number 

Number of  

Cubbies 

Loading Style 

Height 

in             mm 

Depth 

  in               mm 

Width 

   in               mm 

Shipping Weight 

lbs             kg 

PUCA-24S 8 

Front 

78 

1/

       

1994 16 

5/

8

               

422 44 

1/

4

                

1124 

310             141 

PUCA-24S-PT 8 

Pass-Thru 

78 

1/

       

1994 16 

5/

8

               

422 44 

1/

4

                

1124 

310             141 

PUCA-14SAO 4 Front 

78 

1/

       

1994 16 

5/

8

               

422 17 

1/

8

                

 435 

136               62 

PUCA-14SAO-PT 4  Pass-Thru 

78 

1/

       

1994 16 

5/

8

               

422 17 

1/

8

                

 435 

136               62 

PUCH-24S 8 

Front 

78 

1/

       

1994 16 

5/

8

               

422 44 

1/

4

                

1124 

310             141 

PUCH-24S-PT 8 

Pass-Thru 

78 

1/

       

1994 16 

5/

8

               

422 44 

1/

4

                

1124 

310             141 

PUCH-14SAO 4  Front 

78 

1/

       

1994 16 

5/

8

               

422 17 

1/

8

                

 435 

136               62 

PUCH-14SAO-PT 4  Pass-Thru 

78 

1/

       

1994 16 

5/

8

               

422 17 

1/

8

                

 435 

136               62 

PUCA-24SAO-PT 8  Pass-Thru 

78 

1/

       

1994 16 

5/

8

               

422 34 

1/

8

                

 867 

310             141 

PUCA-24SAO 8 Front 

78 

1/

       

1994 16 

5/

8

               

422 34 

1/

8

                

 867 

310             141 

PUCH-24SAO 8  Front 

78 

1/

       

1994 16 

5/

8

               

422 34 

1/

8

                

 867 

310             141 

PUCH-24SAO-PT 8  Pass-Thru 

78 

1/

       

1994 16 

5/

8

               

422 34 

1/

8

                

 867 

310             141 

Specifications

 

PUCA-24S (center) shown 
with two PUCA-14AO 
cabinets on each end 

Note: Model numbers may include C, L or R designation to indicate location of control screen on the front of the cabinet. 

Содержание PUCA-14SAO

Страница 1: ...ece of equip ment Turn OFF the unit anytime the cabinet is not in use If an electrical shock is felt when touching the cabinet dis connect the power immediately and call Carter Hoffmann Technical Serv...

Страница 2: ...vice this appliance 9 DO NOT cover or block any openings on the appliance These appliances are intended to be used for commercial applications for example in kitchens of restau rants canteens hospital...

Страница 3: ...an order code for notification They feature a capacitive touchscreen with scanner for order loading and pick up They can be stand alone for manual order entry or can be integrated with POS software f...

Страница 4: ...nnected via Ethernet or WI FI to generate an order code for notification They feature a capacitive touchscreen with scanner for order loading and pick up They can be stand alone for manual order entry...

Страница 5: ...ning can result in electrical shock Disconnect this appliance from electrical power before performing any maintenance or servicing WARNING Injury Hazard All installation procedures must be performed b...

Страница 6: ...liarize yourself with the appliance controls Read entire manual before operating this cabinet 1 2 3 4 Figure 1 1 Location of bracket screws Floor mount units are shipped with anti slip brackets to aff...

Страница 7: ...net by consulting the serial tag on the cabinet for the model number and electrical rating DO NOT MODIFY CORD PLUG NETWORK CONNECTION 1 Plug network connection into the Ethernet jack located at the re...

Страница 8: ...the black ON OFF switch located at the top rear of the cabinet on the control side The cabinet will turn on and boot up to the home screen on the tablet 1 3 2 NOTE If there are add on cabinets plug in...

Страница 9: ...hen press NETWORK START UP CONNECTING WIFI continued Enter the password for your preferred WiFi network 9 On the ORDER MANAGEMENT screen press the gear symbol Select your preferred WiFi network 4 5 6...

Страница 10: ...CREEN Push in ON OFF switch located at rear of cabinet The cabinet will turn on and boot up to the HOME SCREEN On the HOME Screen press the PUC logo at the top Press 008 on the keypad to access the OR...

Страница 11: ...UAL OPERATION continued To load an order press the icon on the MANAGEMENT SCREEN Press MOBILE PICKUP on the LOAD NEW ORDER SCREEN At the MOBILE PICKUP SCREEN type in the name and phone number for the...

Страница 12: ...ll not allow you to move past this screen if the order is not loaded or if it is placed in the incorrect locker On front loading cabinets close the door s after loading The cabinet will revert to the...

Страница 13: ...e the locker location s for the order The customer can retrieve their order from the locker s and then close the door s TO VIEW CURRENT ORDERS AND OCCUPIED ORDERS 2 Press 008 on the keypad to access t...

Страница 14: ...ess the PUC logo HOME SCREEN On the ORDER MANAGEMENT SCREEN press the gear symbol to go to the CONFIGURE screen ORDER MANAGEMENT PUCH cabinets can operate with or without heat To turn the heat ON or O...

Страница 15: ...re setting function will appear To adjust the temperature setting Press the UP arrow to increase the temperature Press the DOWN arrow to decrease the temperature The temperature setting appears on the...

Страница 16: ...ing strong aromatic solvents or alco hol Use of direct steam hot water cleaning at temperatures above 190 F may result in bubbling or loosening of vinyl adhesive IMPORTANT Cleansers detergents degreas...

Страница 17: ...accordance with the procedures described in the Operation Manual 6 Carter Hoffmann is NOT responsible for any loss of the customer s income loss of food product extra labor charges or any other incide...

Страница 18: ...s under this warranty will be performed unless otherwise authorized in writing by CARTER HOFFMANN at its factory All parts or components to be repaired or replaced under this warranty are to be shippe...

Отзывы: