GB - 4

38VYX050/38VYX080 

Knockout procedure

• The indoor/outdoor connecting pipes can be connected to 4

directions. Take off the knockout part of the pipe cover in which
pipes or wires pass through the base plate.

• As shown in the figure, do not remove the pipe cover from the

cabinet so that the knockout hole can be easily punched.
To knock out, punch the 3 connected parts with a screwdriver and
remove the pipe cover by hand.

• After marking the knockout hole, remove the burr and mount the

attached protective bush and guard material for pass-through part
in order to protect pipes and wires.

• After connecting the pipes, be sure to mount the pipe cover. The

pipe cover is easily mounted by cutting off the slit at the lower part
of the cover.

How to remove the front panel

1. Remove  screws of the front panel.
2. Pull the front panel downward.
Removing the front panel, the electric parts appear at the front side.

The power supply cables can be inserted into the pipe holes.
Enlarge the pipe holes if they are too small.

Be sure to fix the power cable and indoor/outdoor connecting
cable with bundling band sold on the market so that they do not
make contact with the compressor and the hot pipes.
To ensure good tensile strength, the electric cables must be
fastened using the cable-holder on the plate.

Air purge

• For air purge, use a vacuum pump.
• Do not use refrigerant charged in the outdoor unit for air purge.

(The refrigerant for air purge is not contained in the outdoor unit.)

Electrical cabling

• Be sure to fix the power cables and indoor/outdoor connecting

cables with clamps so that they do not contact with the cabinet,
etc.

Installation Place

• A place which provides a specified space around the outdoor unit.
• A place where the operation noise and discharged air are not

given to your neighbors.

• A place that is not exposed to a strong wind.
• A place that does not block a passage.
• When the outdoor unit is installed in an elevated position, be sure

to secure its feet.

• There must be sufficient space for carrying in the unit.
• A place where the drain water does not make any problem.
• If the unit is installed in areas where heavy snowfalls may occur, it

is necessary to raise its level at least  200 mm above the usual
snow level.

CAUTION:

• Install the outdoor unit at a place where discharge air is not blocked.
• When an outdoor unit is installed in a place that is always exposed

to a strong wind like a coast or on a high storey of a building,
secure a normal fan operation by using a duct or a wind shield

• When installing the outdoor unit in a place that is constantly

exposed to a strong wind such as the upper stairs or rooftop of a
building, apply the windproof measures referring to the following
examples.

• Install the unit so that its discharge port faces the wall of the

building. Keep a distance 500 mm or more between the unit and
the wall surface.

• Supposing the wind direction during the operation season of the

air conditioner, install the unit so that the discharge port is set at
right angle to the wind direction.

• Installation in the following places may result in some troubles. Do

not install the unit in such places below.

A place full of machine oil.

A place full of sulphuric gas.

A place where high-frequency radio waves are likely to be
generated as from audio equipment, welders, and medical
equipment.

Selection of installation

 

Strong wind

500

38VYX 080
Cover knockout for pipe connection

 

Rear direction

 

Pipe cover

 

Side direction

 

Down direction

 

Front direction

 Electric parts box

 

Fixing plate

 

Piping hole

 Cable-holder for electric cables

 Front panel

 Strip

Содержание XPOWER 38VYX050

Страница 1: ...38VYX050 38VYX080 L L O Y D S R E G I S TER QUALIT Y A S S U R A N C E IS O 900 1 INSTALLATION MANUAL...

Страница 2: ...refrigerant cylinders are pink R 410A refrigerant cylinders have a dip tube which allows liquid to flow out with the cylinder in a vertical position with the valve at the top R 410A systems should be...

Страница 3: ...other than the specified refrigerant into the refrigeration cycle If air or any other gas is mixed in the refrigerant the gas pressure in the refrigeration cycle becomes abnormally high and it may cau...

Страница 4: ...add refrigerant at installation site 1 from 20 m to 30 m 38VYX 050 Add 20 g of refrigerant for every meter of pipe beyond 20 m 2 from 20 m to 50 m 38VYX 080 Add 40 g of refrigerant for every meter of...

Страница 5: ...round the outdoor unit A place where the operation noise and discharged air are not given to your neighbors A place that is not exposed to a strong wind A place that does not block a passage When the...

Страница 6: ...your fingers Then fix the nut with a spanner and tighten it with torque wrench as shown in the figure As shown in the figure use two spanners to unscrew or tighten the valve flare nut at gas side If u...

Страница 7: ...e lower than the height of the outdoor unit The height of the obstacle should be lower than the height of the outdoor unit 150 or more 300 or more 300 or more 300 or more 200 or more 150 or more 500 o...

Страница 8: ...or more Open the upper side and both right and left sides The height of obstacle at both front and rear side should be lower than the height of the outdoor unit Serial installation at front and rear...

Страница 9: ...nd also seal the screws securely with silicone material etc so that water does not drop down Some conditions may cause dewing or dripping of water Drain nipple Table VI Optional Installation Parts loc...

Страница 10: ...ed valve Gas side a little to check the air passes through 2 Tighten the flare nut again Execute vacuuming until the compound pressure gauge indicates 101kPa 76cmHg 1 Close handle Low completely Turn...

Страница 11: ...g disconnect electrical connections before refrigerant connections IMPORTANT Make ground connection prior to any other electrical connections Power cable and connecting cable The installation fuse 25A...

Страница 12: ...ashing Discharge temp error hot gas is too high Off EEPROM error On Communication error between IPDU No abnormal stop G Tr short circuit protection Detect circuit error Current sensor error Comp lock...

Страница 13: ...other refrigerant from being charged each port diameter is changed In order to increase pressure resisting strength Charge hose x hose materials and port size are changed to 1 2 UNF 20 threads per in...

Страница 14: ...050 080 Via R Sanzio 9 20058 Villasanta MI Italy Tel 039 3636 1 The manufacturer reserves the right to change any product specifications without notice November 2003 Supersedes July 2003 Printed in J...

Отзывы: