20
2281.37
89.82
[]
408.89
16.10
[]
UNIT MOUNTING
2769.30
109.03
[]
812.70
32.00
[]
UNIT MOUNTING
2769.30
109.03
[]
408.89
16.10
[]
2073.54
81.64
[]
7169.08
282.25
[]
3208.00
126.30
[]
800.00
31.50
[]
1781.62
70.14
[]
1773.54
69.82
[]
755.58
29.75
[]
2236.08
88.03
[]
934.00
36.77
[]
200.00
7.87
[]
100.00
3.94
[]
y
CG
CG
x
960.40
37.81
[]
400.00
15.75
[]
240.00
9.45
[]
246.36
9.70
[]
336.50
13.25
[]
39.89
1.57
[]
UNIT MOUNTING
2156.30
84.89
[]
200.00
7.87
[]
200.00
7.87
[]
2X
343.58
13.53
[]
343.81
13.54
[]
553.81
21.80
[]
5087.45
200.29
[]
3344.54
131.67
[]
1892.50
74.51
[]
4459.04
175.55
[]
601.22
23.67
[]
PIPING ENETRANCE AREA
600.00
23.62
[]
PIPING ENETRANCE AREA
600.00
23.62
[]
PIPING ENETRANCE AREA
600.00
23.62
[]
162.77
6.41
[]
2X
503.37
19.82
[]
2X
769.85
30.31
[]
938.35
36.94
[]
215.55
8.49
[]
WEIGHT
MCHX lb/kg
CENTER OF GRAVITY
CGx
MM [INCH]
CGy
MM [INCH]
30RB-190,
360A,390A/B
12850 5706
3566
[140.39]
979
[38.54]
CIRCUIT B
COMPRESSORS
SCROLLING MARQUEE
DISPLAY
CIRCUIT A
COMPRESSORS
A
A
HR CONDENSER TUBE SERVICE AREA
COOLER VENT 1/4" NPT
COOLER DRAIN
3/4" NPT
COOLER LEAVING WATER 6" VICTAULIC
COOLER ENTERING WATER 6" VICTAULIC
CONDENSER DRAIN 3/8" NPT
AIR FLOW
FIELD CONTROL WIRING
FAN ELECTRICAL BOX
(FEB)
ALL VOLTAGES
POWER BOX 230V ONLY (CKT A)
7/8" KNOCKOUT TO BE
USED FOR LOCATING FIELD POWER WIRING
(DUAL POINT 230V ONLY)
BACnet COMMUNICATION OPTION KNOCKOUT FOR 1/2" CONDUIT
COOLER TUBE SERVICE AREA
SERVICE AREA 1219.2[48.0] FROM EACH SIDE OF THE UNIT
SEE DETAIL
B
VIEW A-A
SCALE
1:32
7/8" KNOCKOUT TO BE
USED FOR LOCATING FIELD POWER WIRING
(DUAL AND SINGLE POINT)
POWER BOX 230V (CKT B) POWER BOX 380V,460V,575V (CKT A,B)
DETAIL
B
SCALE
1:4
22.2 [.87]
MOUNTING HOLE
CONDENSER ENTERING WATER 5.0" VICTAULIC
CONDENSER LEAVING WATER 5.0" VICTAULIC
CONDENSER VENT 1/4" NPT
N
O
TES:
1.
U
n
it
must
ha
ve
clea
rances
as f
oll
ows:
T
o
p —
D
o
not
restrict.
Sides and
En
d — 6
(1.
8
m) f
ro
m solid
surf
ace.
2.
T
e
mperat
ur
e re
lief
de
vi
ce
s
locat
ed
on suct
ion
line,
l
iquid
lin
e an
d f
ilt
er
drier
of each circuit
and have
1
/
4
fl
are conne
ct
ion
.
3.
D
imensions are in mm [in
c
h
e
s].
4.
Allow 8
ft
(2
.4
m) of
service a
c
cess on
eit
her
si
de o
f u
nit
fo
r conde
nser coi
l
removal.
a30-4740
L
E
G
E
ND
HR
—
He
at Reclaim
MCHX
—
Mi
cr
ochanne
l Co
nden
se
r Co
il
Fi
g.
1
6 — 30
RB1
90 Air
-Cool
ed
Chi
ll
e
r wi
th Hea
t Recl
ai
m Opt
io
n Di
men
si
ons