10
224.84
8.85
[]
PIPING ENTRANCE AREA
2446.09
96.30
[]
916.15
36.07
[]
z
PD
z
PS
761.94
30.00
[]
2236.08
88.03
[]
CG
x
y
CG
2281.37
89.82
[]
3587.08
141.22
[]
408.89
16.10
[]
408.89
16.10
[]
PD
x
515.82
20.31
[]
PS
x
2728.56
107.42
[]
391.88
15.43
[]
PS
y
PD
y
860.81
33.89
[]
246.36
9.70
[]
336.50
13.25
[]
190.00
7.48
[]
200.00
7.87
[]
45.00
1.77
[]
100.00
3.94
[]
RIGGING HOLE
38.00
1.50
[]
UNIT MOUNTING
2769.30
109.03
[]
1447.8[57.0]
UNIT MOUNTING
2156.30
84.89
[]
992.44
39.07
[]
2438.40 [96.00]
938.35
36.94
[]
39.89
1.57
[]
215.73
8.49
[]
WEIGHT CU/AL lb/kg
MAX WEIGHT CU/AL PUMP
lb/kg
WEIGHT CU/CU lb/kg
MAX WEIGHT CU/CU PUMP
lb/kg
WEIGHT
MCHX lb/kg
MAX WEIGHT MCHX PUMP
lb/kg
CENTER OF GRAVITY
PUMP SUCTION (PS)
PUMP DISCHARGE (PD)
CGx
MM [INCH]
CGy
MM [INCH]
X .25
Y .25
Z .25
X .25
Y .25
Z .25
30RB-110
6519 2963
7442 3383
7243 3292
8166 3712
6027 2734
6950 3152
1713
[67.44]
997
[39.25]
856.0 [33.7]
281.9 [11.1]
60.9 [2.4]
340.4 [13.4]
391.2 [15.4]
233.7 [9.2]
CIRCUIT A
COMPRESSORS
CIRCUIT B
COMPRESSORS
FAN ELECTRICAL BOX
(230V ONLY)
(FEB)
AIR FLOW
COIL SERVICE AREA
COIL SERVICE AREA
COOLER VENT
1/4"
NTP
COOLER DRAIN
3/4" NPT
PUMP PACKAGE
LEAVING WATER
6" VICTAULIC
NO PUMP PACKAGE ENTERING WATER 6" VICTAULIC (SEE NOTE 4)
SEE DETAIL
B
PUMP PACKAGE ENTERING WATER 6" VICTAULIC
COOLER TUBE SERVICE AREA
SERVICE AREA 1219.2[48.0] FROM EACH SIDE OF THE UNIT
DETAIL
B
SCALE
3:16
22.2[.87]
MOUNTING HOLE
POWER BOX 230V CONTROL/POWER BOX 380V,460V,575V
7/8" KNOCKOUT TO BE USED FOR LOCATING FIELD POWER WIRING
SCROLLING MARQUEE
DISPLAY
BACnet COMMUNICATION OPTION KNOCKOUT FOR 1/2" CONDUIT
FIELD CONTROL WIRING
NOT
E
S:
1
.
Uni
t must have clear
ances
a
s
f
o
llows:
Top — Do
not
restrict
.
S
ides and End
—
6
(
1
.8
m
) fr
o
m
so
lid
su
rf
a
c
e
.
A
irflow Sid
e
— 8
(
2
.4
m) re
quire
d f
o
r coil
s
e
rvice
ar
ea.
2
.
A
ll pu
mps have d
rain
s
locat
ed a
t t
he
bot
to
m of
volu
te f
o
r drai
ning.
3
.
Temp
erat
ure
re
lief
de
vi
ce
s ocat
ed on suctio
n
line,
liquid
line
and
fil
ter
dri
e
r o
f e
a
ch circuit
a
nd h
a
ve
1
/
4
fl
are
conn
ectio
n
.
4
.
No
pump p
acka
ge l
eaving
w
a
te
r conne
ct
ion
is
same size and ha
s same Y an
d Z
dime
nsions as
en
te
ring wat
e
r.
Also has
same
PDx
di
mension as
pu
mp package.
5
.
Dimen
si
ons
a
re in mm
[i
nche
s]
.
a30 5332
MCHX — Microchan
nel Cond
enser Coil
Fig. 6 —
3
0
RB1
1
0
Air-Coo
le
d
Ch
iller Dime
nsions