4.3.14.2 - DESCRIPTION OF RUNTIMES 2 MENU
4.3.14.3 - DESCRIPTION OF THE RUNTIMES 3 MENU
4.3.14.4 - MAINTENANCE MENU DESCRIPTION
To be active, the maintenance function must be preset in
the Service configuration
1
This item is masked when not used
ITEM #
0
1 [1]
2 [1]
3 [1]
4
5
6 [1]
7 [1]
8 [1]
9 [1]
10 [1]
11 [1]
12 [1]
13 [1]
14 [1]
15 [1]
FORMAT
RuntiME 2 menu
nnnn | M 10 | M100
nnnn | M 10 | M100
nnnn | M 10 | M100
nnnn
nnnn
nnnn | M 10 | M100
nnnn | M 10 | M100
nnnn | M 10 | M100
nnnn | M 10 | M100
nnnn | M 10 | M100
nnnn | M 10 | M100
nnnn | M 10 | M100
nnnn | M 10 | M100
nnnn | M 10 | M100
nnnn | M 10 | M100
UNITS
-
hrs/10 or 100
hrs/10 or 100
hrs/10 or 100
-
-
hrs/10 or 100
hrs/10 or 100
hrs/10 or 100
hrs/10 or 100
-/10 or 100
-/10 or 100
-/10 or 100
-/10 or 100
-/10 or 100
-/10 or 100
COMMENTS
When selected this item
authorises return to the
previous menu
Pump 1 operating hours*
Pump 2 operating hours*
Heat reclaim condenser pump
operating hours
Compressor starts for
compressor with most starts
during the last hour
24 hours average number of
starts/hour, compressor
Compressor C1 operating
hours
Compressor C2 operating
hours
Compressor C3 operating
hours
Compressor C4 operating
hours
Compressor C1 starts
Compressor C2 starts
Compressor C3 starts
Compressor C4 starts
No. of defrost cycles, circuit A
No. of defrost cycles, circuit B
RUNTIMES MENU [1]
ITEM #
0
1
2
3 [1]
4 [1]
5 [1]
6 [1]
7
8
9 [1]
10 [1]
11 [1]
12 [1]
13 [1]
14 [1]
15 [1]
16 [1]
17 [1]
18 [1]
FORMAT
RuntiME 3 menu
nnnn | M 10 | M100
nnnn | M 10 | M100
nnnn | M 10 | M100
nnnn | M 10 | M100
nnnn | M 10 | M100
nnnn | M 10 | M100
nnnn | M 10 | M100
nnnn | M 10 | M100
nnnn | M 10 | M100
nnnn | M 10 | M100
nnnn | M 10 | M100
nnnn | M 10 | M100
nnnn | M 10 | M100
nnnn | M 10 | M100
nnnn | M 10 | M100
nnnn | M 10 | M100
nnnn | M 10 | M100
nnnn | M 10 | M100
UNITS
-
hrs/10 or 100
hrs/10 or 100
hrs/10 or 100
hrs/10 or 100
hrs/10 or 100
hrs/10 or 100
hrs/10 or 100
hrs/10 or 100
hrs/10 or 100
hrs/10 or 100
hrs/10 or 100
hrs/10 or 100
hrs/10 or 100
hrs/10 or 100
hrs/10 or 100
hrs/10 or 100
hrs/10 or 100
hrs/10 or 100
COMMENTS
When selected this item
authorises return to the
previous menu
Fan A1 operating hours
Fan A2 operating hours
Fan A3 operating hours
Fan A4 operating hours
Fan A5 operating hours
Fan A6 operating hours
Fan B1 operating hours
Fan B2 operating hours
Fan B3 operating hours
Fan B4 operating hours
Fan B5 operating hours
Fan B6 operating hours
Fan C1 operating hours
Fan C2 operating hours
Fan C3 operating hours
Fan C4 operating hours
Fan C5 operating hours
Fan C6 operating hours
RUNTIMES MENU
1
This item is masked when not used
ITEM #
0
1 [1]
2 [1]
3 [1]
4 [1]
5 [1]
6 [1]
7 [1]
FORMAT
MAintEnAnCE MEnu
0 to 6
YES/no
YES/no
nnnn
nnnn
nnnn
nnnn
DESCRIPTION
When selected this item authorises return to
the previous menu.
Deletes the maintenance alerts.
Refrigerant control.
Water loop rate to low
Next primary pump maintenance operation in
nnn days. If the number of days = 0, the delay
before maintenance has elapsed.
Next secondary pump maintenance operation
in nnn days. If the number of days = 0, the
delay before maintenance has elapsed.
Next maintenance operation on the heat
reclaim condenser pump. If the number of
days = 0, the delay before maintenance has
elapsed.
Next water filter maintenance operation in nnn
days. If the number of days = 0, the delay
before maintenance has elapsed.
1
This item is masked when not used.