T-359
4–24
NOTE
Configuration numbers not listed are not used in this application. These items may appear when load-
ing configuration software to the controller but changes will not be recognized by the controller pro-
gramming.
CnF45
Low Humidity Enabled
Out
In
CnF47
Fresh Air Vent Position Sensor
OFF
UP, LOW,
CUStOM
CnF49
DataCORDER Configuration Restore
OFF
On
CnF50
Enhanced Bulb Mode Selection
OFF
Bulb, dEHUM
CnF51
Timed Defrost Disable
0
0-out, 1-in
CnF52
Oil Return Algorithm
1
0-out, 1-in
CnF53
Water Cool Oil Return Logic
0
0-out, 1-in
CnF55
TXV Boost Relay
0
0-out, 1-in
CnF56
TXV Boost Circuit
0
0-out, 1-in
CnF59
Electronic Expansion Valve
0
0-none, 1-EC,
2-KE, 3- NA
CnF60
Compressor-Cycle Perishable Cooling
0
0-out, 1-in
CnF61
ACT ASC Control Enable
0
0-out, 1-in
CnF62
Extended Temperature Control Enable
0
0-on, 1-in
CnF63
CCPC Pre-trip/Tripstart Default State
0
0-on, 1-off
CnF64
Evaporator Fan Pulsing Logic Enable
0
0-in, 1-out
Table 4–4 Controller Configuration Variables (Continued)
CONFIG #
TITLE
DEFAULT
OPTION
Содержание 69NT40-561-019
Страница 2: ......
Страница 4: ......
Страница 74: ......
Страница 127: ...8 3 T 359 Figure 8 2 SCHEMATIC DIAGRAM Evergreen Unit Configuration ...
Страница 128: ...T 359 8 4 Figure 8 3 UNIT WIRING DIAGRAM Evergreen Unit Configuration Sheet 1 of 2 ...
Страница 129: ...8 5 T 359 Figure 8 4 UNIT WIRING DIAGRAM Evergreen Unit Configuration Sheet 2 of 2 ...
Страница 130: ......
Страница 134: ......
Страница 135: ......