T-359
3–4
3.1.5
Air-Cooled Condenser Section
The air-cooled condenser section (
) consists of the condenser fan, condenser coil, receiver, liquid line
service valve, filter drier, fusible plug, economizer, economizer expansion valve, economizer solenoid valve (ESV),
and sight glass/moisture indicator.
The condenser fan pulls air through the bottom of the coil and discharges it horizontally through the con denser fan grille.
Figure 3.4 Air-Cooled Condenser Section
1. Grille and Venturi Assembly
2. Condenser Fan
3. Key
4. Condenser Fan Motor
5. Condenser Coil
6. Condenser Coil Cover
7. Receiver
8. Sight Glass
9. Filter Drier
10. Economizer
11. Economizer Solenoid Valve (ESV)
12. Economizer Expansion Valve
13. Service Access Valve
14. Liquid Level/Moisture Indicator
15. Fusible Plug
- - - - -