![Carrier 69NT40-561-019 Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/carrier/69nt40-561-019/69nt40-561-019_operation-and-service-manual_2563845018.webp)
T-359
3–2
3.1.3
Evaporator Section
The evaporator section (
) contains the return temperature sensor, humidity sensor, electronic expansion
valve, dual speed evaporator fans (EM1 and EM2), evaporator coil and heaters, defrost temperature sensor, heat
termination thermostat and evaporator temperature sensors (ETS1 and ETS2).
The evaporator fans circulate air through the container by pulling it in the top of the unit, directing it through the
evaporator coil, where it is heated or cooled, and discharging it at the bottom.
Most evaporator components are accessible by removing the upper rear panel (as shown in the illustration) or by
removing the evaporator fan access panels (see
, Items 1 and 16).
Figure 3.2 Evaporator Section
1. Evaporator Fan Motor #1 (EM1)
2. Return Recorder Sensor/Temperature Sensor
(RRS/RTS)
3. Humidity Sensor (HS)
4. Evaporator Fan Motor #2 (EM2)
5. Evaporator Coil
6. Evaporator Coil Heaters (Underside of Coil)
7. Heater Termination Thermostat (HTT)
8. Defrost Temperature Sensor (DTS)
9. Electronic Expansion Valve (EEV)
10. Evaporator Temperature Sensors (Location)
(ETS1 and ETS2)
11. Interrogator Connector (Rear) (ICR)
12. USDA Probe Receptacle PR2
13. USDA Probe Receptacle PR1
14. USDA Probe Receptacle PR3
15. Cargo Probe Receptacle PR4
- - - - -
Содержание 69NT40-561-019
Страница 2: ......
Страница 4: ......
Страница 74: ......
Страница 127: ...8 3 T 359 Figure 8 2 SCHEMATIC DIAGRAM Evergreen Unit Configuration ...
Страница 128: ...T 359 8 4 Figure 8 3 UNIT WIRING DIAGRAM Evergreen Unit Configuration Sheet 1 of 2 ...
Страница 129: ...8 5 T 359 Figure 8 4 UNIT WIRING DIAGRAM Evergreen Unit Configuration Sheet 2 of 2 ...
Страница 130: ......
Страница 134: ......
Страница 135: ......