T-354
4–32
Table 4–8 DataCORDER Pre-Trip Records
NOTE
Inapplicable Functions Display "
-----
"
To Access: Press ALT. MODE key
CODE
TITLE
DESCRIPTION
dC1
Recorder Supply
Temperature
Current reading of the supply recorder sensor.
dC2
Recorder Return
Temperature
Current reading of the return recorder sensor.
dC3-5
USDA 1,2,3
Temperatures
Current readings of the three USDA probes.
dC6-13
Network Data
Points 1-8
Current values of the network data points (as configured). Data point
1 (Code 6) is generally the humidity sensor and its value is obtained
from the Controller once every minute.
dC14
Cargo Probe 4
Temperature
Current reading of the cargo probe #4.
dC15-19
Future Expansion
These codes are for future expansion, and are not in use at this time.
dC20-24
Temperature Sensors
1-5 Calibration
Current calibration offset values for each of the five probes: supply, re-
turn, USDA #1, #2, and #3. These values are entered via the interro-
gation pro gram.
dC25
Future Expansion
This code is for future expansion, and is not in use at this time.
dC26,27
S/N, Left 4, Right 4
The DataCORDER serial number consists of eight characters. Func-
tion code dC26 contains the first four characters. Function code dC27
contains the last four characters. (This serial number is the same as
the Controller serial number)
dC28
Minimum Days Left
An approximation of the number of logging days remaining until the
Data CORDER starts to overwrite the existing data.
dC29
Days Stored
Number of days of data that are currently stored in the DataCORDER.
dC30
Date of last Trip start
The date when a Trip Start was initiated by the user. In addition, if the
system goes without power for seven continuous days or longer, a trip
start will automatically be generated on the next AC power up.
dC31
Battery Test
Shows the current status of the optional battery pack.
PASS
: Battery pack is fully charged.
FAIL
: Battery pack voltage is low.
dC32
Time: Hour, Minute
Current time on the real-time clock (RTC) in the DataCORDER.
dC33
Date: Month, Day
Current date (month and day) on the RTC in the DataCORDER.
dC34
Date: Year
Current year on the RTC in the DataCORDER.
dC35
Cargo Probe 4 Calibration
Current calibration value for the Cargo Probe. This value is an input
via the interrogation program.
Содержание 69NT40-541-306
Страница 2: ......
Страница 4: ......
Страница 10: ......
Страница 14: ......
Страница 78: ...T 354 5 8 Figure 5 3 Controller Operation Perishable Mode Figure 5 4 Controller Operation Frozen Mode ...
Страница 142: ...T 354 8 2 Figure 8 2 Schematic Diagram Standard Unit Configuration BASED ON 62 66686 00 ...
Страница 143: ...8 3 T 354 Figure 8 3 Unit Wiring Diagram Standard Unit Configuration 1 of 2 BASED ON 62 66686 00 ...
Страница 144: ...T 354 8 4 Figure 8 4 Unit Wiring Diagram Standard Unit Configuration 2 of 2 BASED ON 62 66686 00 ...
Страница 148: ...T 354 8 8 ...
Страница 152: ......
Страница 153: ......