![Carrier 69NT40-541-306 Скачать руководство пользователя страница 140](http://html1.mh-extra.com/html/carrier/69nt40-541-306/69nt40-541-306_operation-and-service_2563729140.webp)
T-354
7–52
Figure 7.37 R-134a Compressor Pressure & Motor Current Curves Versus Ambient Temperature (2 of 2)
--6
--4
--2
0
2
4
6
8
10
12
14
60
70
80
90
100
110
120
Ambient Air Temperature
psig
(Bar)
(.97)
(.83)
(.69)
(.55)
(.41)
(.28)
(.14)
(0)
(-.14)
(-.28)
(-.41)
0
_
F (-17.8
_
C) Box
(48.9)
(43.3)
(37.8)
(32.2)
(26.7)
(21.1)
(15.6)
35
_
F (1.7
_
C) Box
Compressor Suction Pressure Versus Ambient Air Temperature at Stable Box Temperature
8
9
10
11
12
13
14
15
16
17
60
70
80
90
100
110
120
Ambient Air Temperature
Compressor-Motor Current Versus Ambient Air Temperature At Stable Box Temperature
35
_
F (1.7
_
C) Box
0
_
F (-17.8
_
C) Box
(48.9)
(43.3)
(37.8)
(32.2)
(26.7)
(21.1)
(15.6)
(
_
C)
(
_
F)
(
_
C)
(
_
F)
Содержание 69NT40-541-306
Страница 2: ......
Страница 4: ......
Страница 10: ......
Страница 14: ......
Страница 78: ...T 354 5 8 Figure 5 3 Controller Operation Perishable Mode Figure 5 4 Controller Operation Frozen Mode ...
Страница 142: ...T 354 8 2 Figure 8 2 Schematic Diagram Standard Unit Configuration BASED ON 62 66686 00 ...
Страница 143: ...8 3 T 354 Figure 8 3 Unit Wiring Diagram Standard Unit Configuration 1 of 2 BASED ON 62 66686 00 ...
Страница 144: ...T 354 8 4 Figure 8 4 Unit Wiring Diagram Standard Unit Configuration 2 of 2 BASED ON 62 66686 00 ...
Страница 148: ...T 354 8 8 ...
Страница 152: ......