   occupied

Su

1

Programming         

Occupied & Unoccupied Periods

Page 11

Adjust the start time
for occupied 1.

Adjust the stop time
for occupied 1.

Select the day
for Occupied 1. 

Select Occupied 1 to run
on this day (On), or not to
run this day (Off).

Off

On

   occupied

ON

Su

1

   occupied

Pm

Stop

Su

1

 5:00

  occupied

Am

Start

Su

1

 9:00

Press

Press

Press

MODE

MODE

MODE

Press the Mode button. While holding the Mode,
press the Up button for 2 seconds to exit 
time period programming.

MODE

To Exit Programming

Содержание 50QE900-511WS

Страница 1: ...ge Easy To Read Display Thermoglow Backlight No Batteries Required Auto Changeover Energy Saving Smart Fan Locking Keypad Override Button Meets California Title 24 Designed for Commercial Water Source Heat Pumps Commercial Systems Services Carrier Corporation 3 00 Carrier 72 74 70 COOL HEAT AUTO Mo I2 00 Carrier Includes Locking Cover A Q U A Z O N E ...

Страница 2: ... Unoccupied ADVANCED SETUP ABOUT ADVANCED OPERATION WARRANTY Page 1 CAUTION Follow Installation Instructions before proceeding SET THERMOSTAT TO MODE OFF PRIOR TO CHANGING SETTINGS IN SETUP OR RESTORING FACTORY DEFAULTS P N 50QE900 511WS 2 3 5 6 8 13 17 22 Commercial Systems Services Carrier Corporation 3 00 ...

Страница 3: ...ont Panel Page 2 Liquid Crystal Display with Thermoglow Up Down Buttons Mode Button Override Button Heat or Cool Indicator Heat Red Cool Green 1 2 3 4 5 2 3 4 5 1 72 74 70 COOL HEAT AUTO Mo I2 00 Carrier ...

Страница 4: ... temperature varies OFF indicates the entire system is turned off PROGRAM ON indicates the stored program is enabled to run Page 8 Clock with Day of the Week Indicates the current time and day This clock is also used to program the timer periods Page 13 Room Temperature Display Indicates the current room temperature Desired Set Temperature Indicates desired room temperature s Page 7 Display Page 3...

Страница 5: ... the thermostat is in the programming mode Page 13 Fan Operation Indication Fan On indicates constant continuous fan operation When Fan On is not lit indicates the fan will only operate when necessary to heat or to cool Page 13 Locked Indication Locked appears after the right combination of buttons are pressed rendering the buttons inoperative Page 19 Start Stop Indication Start or Stop appears wh...

Страница 6: ...nds to enter Setup screens Press both Mode and Override buttons as above to return to normal operation Quick Start Set the Clock and Go Page 5 The thermostat is preprogrammed from the factory to operate 1 or 2 Stage equipment without the need for further programming To optimize the installation of this thermostat follow the instructions in the Advanced Setup section buttons To adjust the clock or ...

Страница 7: ...n to cool the room OFF indicates both heating and air conditioning systems are turned off AUTO will automatically select heat or cool based on room temperature demand Program On will activate the stored timer operation occupied unoccupied periods Select Mode Basic Operation Page 6 Press MODE Press MODE Press MODE Press MODE 70 I2 00 69 Su 70 72 I2 00 Su 70 72 I2 00 69 Su 70 73 I2 00 70 Su occupied...

Страница 8: ...mporarily With each successive push of the Override button the override timer will add 30 minutes until the maximum of 4 hours is reached Then the next press will zero out the override timer returning to unoccupied if there are no further button presses When in Override the Override icon and the Occupied 1 icon appear on the display The time of day clock alternates with the time remaining in overr...

Страница 9: ...riod programming Continued Select the maximum of occupied periods to be used on any one day Typically 1 1 2 or 3 Adjust the cooling setpoint for occupied 1 Adjust the cooling setpoint for unoccupied periods Adjust the heating setpoint for occupied 1 35 99 35 99 35 99 MODE MODE MODE MODE MODE Occupied 1 74 Occupied COOL 1 74 72 Occupied COOL HEAT 1 85 unoccupied COOL ...

Страница 10: ... Select the day for Occupied 1 Adjust the stop time for occupied 1 Select Occupied 1 to run on this day On or not to run this day Off Adjust the start time for occupied 1 MoTuWeThFr Sa Su Off On MODE MODE MODE MODE 55 unoccupied HEAT Occupied MoTuWeThFr 1 Occupied Am Start MoTuWeThFr 1 7 00 Occupied Pm Stop MoTuWeThFr 1 6 00 Occupied ON MoTuWeThFr 1 ...

Страница 11: ...he start time for occupied 1 Adjust the stop time for occupied 1 Select the day for Occupied 1 Sa Su MoTuWeThFr MODE MODE MODE MODE Occupied Sa 1 occupied Am Start Sa 1 9 00 occupied Pm Stop Sa 1 5 00 Select Occupied 1 to run on this day On or not to run this day Off Off On occupied 1 Su On ...

Страница 12: ...ct the day for Occupied 1 Select Occupied 1 to run on this day On or not to run this day Off Off On occupied ON Su 1 occupied Pm Stop Su 1 5 00 occupied Am Start Su 1 9 00 Press Press Press MODE MODE MODE Press the Mode button While holding the Mode press the Up button for 2 seconds to exit time period programming MODE To Exit Programming ...

Страница 13: ...program will run from 12 00am MTWTF to 8 00am MTWTF and again midnight and from midnight to from 9 00pm MTWTF to 12 00pm MTWTF The Unoccupied settings take effect at all times when 1 the program is on and 2 the current time is outside a preset occupied period If the same start and stop times are programmed in for an occupied period then it will run 24 hours If one occupied period starts and stops ...

Страница 14: ...ess the Mode button While holding the Mode press the Override button for 5 seconds to enter Setup screens NOTE Each step is located at the top right corner of the display for easy reference Display On Display Off Fan On Fan Off Tip To change hours quickly press and hold the override button in and press the up or down buttons OVERRIDE MODE MODE MODE MODE MODE I Am Setup I2 00 2 Setup Mo dsp 3 ON Se...

Страница 15: ...tpoints Adjust the deadband from 1 6 degrees 0 6 81f MODE MODE MODE MODE 2 5 Setup 88 2 6 COOL HEAT Setup Select the display back light always On or Off after 8 seconds On Off Select the cycles per hour limit d cycles per hour limit defeated d1 d defeat 5 min Compressor lockout d d1 2 6 6 7 Cy Setup Setup L I 8 ON ...

Страница 16: ... the Mode button While holding the Mode press the Override button for 2 seconds to leave the Setup screens If no buttons are pressed the display will leave the setup screens after 30 seconds Press MODE Setup F 9 OVERRIDE MODE Select the reversing valve polarity for Heat Pump O or B B O 0 I0 Setup ...

Страница 17: ...the week Sun Sat Monday 3 Display Blanking Off On On 4 Fan operation Auto On Auto 5 6 7 8 9 10 Deadband or Temperature swing 1 6 2 Forced minimum difference heat cool 0 6 2 Cycles per hour d d1 2 6 6 Thermoglow backlight Off On On Fahrenheit or Centigrade F C F Reversing Valve polarity O B O Advanced Setup Table ...

Страница 18: ...ol setpoints will not be allowed to come any closer to each other than the value set in Advanced Setup step 6 on page 14 This minimum difference is enforced during Auto changeover operation and Program On ENERGY SAVING SMART FAN If Fan On is selected page 13 step 4 the fan will run continuously at all times except in Off and will only run if there is a heating or cooling demand in Unoccupied perio...

Страница 19: ...splay will read EH During Emergency Heat the thermostat will turn on the fan and the 2nd stage of heat when there is a demand for heat locking out the 1st stage compressor Exiting Emergency Heat is the same as entering During Emergency Heat only OFF and HEAT are available To turn on Emergency Heat press in the Press for Emergency Heat OVERRIDE 73 eh I2 00 74 Su ...

Страница 20: ...ock the buttons again press and hold the Mode button While holding the Mode button in press the Up and Down buttons in together The Locked icon will disappear from the display The thermostat display may be configured in advanced setup page 13 step 3 to always be visible as normally expected or may be selected Off When selected Off only the time of day will appear until a button is pressed When a b...

Страница 21: ...to mode from Cool the Heat and Cool setpoints will remain spread apart by the amount that they were adjusted prior to entering Auto For example If the Cool setpoint was set to 80 while in the Cool mode and the Heat setpoint was adjusted to 70 while in the Heat mode upon entering the Auto mode the Heat and Cool setpoints would be 80 and 70 Both setpoints would then move up and down together in this...

Страница 22: ... sec All icons will appear Press and hold in the Override button until Fd appears This resets all factory settings To calibrate room temperature press the Mode button once more At this point use the Up and Down buttons to calibrate room temperature if needed Press the Mode button to return to normal operation NOTE CAUTION ON PAGE 1 LOCKING COVER w Tamper Proof Screws 72 72 74 74 70 70 COOL COOL HE...

Страница 23: ...ENTPARTS WHETHERNEWOR REMANUFACTURED ASSUMEASTHEI RWARRANTYPERI ODONLYTHEREMAI NI NG TI MEPERI ODOFTHI SWARRANTY THECOMPANYWI LLNOTBERESPONSI BLEFOR 1 Nor mal mai nt enanceasout l i nedi nt hei nst al l at i onandser vi ci ngi nst r uct i onsor owner s manual i ncl udi ngf i l t er cl eani ngand or r epl acement andl ubr i cat i on 2 Damageor r epai r sr equi r edasaconsequenceof f aul t yi nst al...