background image

Packaged rooftop units 

with integrated gas burner

2

Contents

1. Introduction 

.......................................................................................................................................................................................................3

2. Operation 

limits 

.................................................................................................................................................................................................3

3.   Technical characteristics ...................................................................................................................................................................................4

4. General 

recommendations 

................................................................................................................................................................................5

Delivery of the unit ............................................................................................................................................................................................5

Unit identifi cation ...............................................................................................................................................................................................5

Documentation provided ...................................................................................................................................................................................5

Location .............................................................................................................................................................................................................5

Installation .........................................................................................................................................................................................................5

Unit maintenance ..............................................................................................................................................................................................5

Safety advice .....................................................................................................................................................................................................5

Refrigerant safety ..............................................................................................................................................................................................6

Burner safety .....................................................................................................................................................................................................6

5. Transport 

...........................................................................................................................................................................................................6

Gravity centre ....................................................................................................................................................................................................7

6.  Location and assembling ..................................................................................................................................................................................7

Location designation .........................................................................................................................................................................................7

Sound Level ......................................................................................................................................................................................................7

Anchorage for antivibrators ...............................................................................................................................................................................8

Minimum free space for commissioning and maintenance operations .............................................................................................................8

7. Gas 

Burner 

........................................................................................................................................................................................................9

Operating principle ............................................................................................................................................................................................9

Control of the gas burner ................................................................................................................................................................................10

8. Safety 

elements 

..............................................................................................................................................................................................11

Safety devices in the gas burner .....................................................................................................................................................................11

Safety devices in the 48EN/EH unit ................................................................................................................................................................12

9.  Checking before commissioning .....................................................................................................................................................................13

Electrical Connections .....................................................................................................................................................................................13

Gas Burner ......................................................................................................................................................................................................13

Air ducts connections ......................................................................................................................................................................................15

Checks in the axial fans ...................................................................................................................................................................................15

Checks in the centrifugal fans .........................................................................................................................................................................15

Condensate drain connection .........................................................................................................................................................................16

10.  Starting the unit ...............................................................................................................................................................................................17

Checks prior to commissioning .......................................................................................................................................................................17

Operational checks .........................................................................................................................................................................................17

Possible problems at commissioning ..............................................................................................................................................................17

11. Options ............................................................................................................................................................................................................18

Pre-assembly frames (optional) ......................................................................................................................................................................18

Outdoor coil protection grille ...........................................................................................................................................................................18

Filters ..............................................................................................................................................................................................................18

Stop-drop ........................................................................................................................................................................................................18

12. Maintenance ....................................................................................................................................................................................................19

13. Control and analysis of breakdowns................................................................................................................................................................22

Содержание 48EH

Страница 1: ...ERATION AND MAINTENANCE INSTRUCTIONS 48EN EH Nominal cooling capacity 58 9 135 5 kW Nominal heating capacity 62 2 143 4 kW 50 Hz Packaged rooftop cooling only heat pumps with integrated gas burner Ori...

Страница 2: ...ommissioning and maintenance operations 8 7 Gas Burner 9 Operating principle 9 Control of the gas burner 10 8 Safety elements 11 Safety devices in the gas burner 11 Safety devices in the 48EN EH unit...

Страница 3: ...lation and reliable operation Space 48EN Series Autonomous air air cooling units with a compact horizontal rooftop design with a built in gas burner Space 48EH Series Autonomous reversible air air hea...

Страница 4: ...5 900 18 000 18 200 20 400 24 000 Available static pressure mm w c 12 12 12 12 12 12 12 12 15 15 Type Centrifugal Number no turbines 2 2 Motor output kW 2 x 1 5 2 x 2 2 2 x 3 2 x 1 1 2 x 2 2 2 x 2 2 2...

Страница 5: ...ents during installation commissioning or maintenance it is required to take into consideration the units specifications refrigerated circuits under pressure refrigerant presence voltage presence and...

Страница 6: ...said vapours Although the R 410A is not flammable when in contact with a flame or hot spot it can decompose thus producing fluorhydric acid HF and fluophosgene COF2 which are highly toxic and corrosiv...

Страница 7: ...re can withstand the weight of the unit Since the unit is designed to work outdoors some specific installation norms must be followed The unit will be located on the roof of the premises If it is fore...

Страница 8: ...02 450 404 66 414 368 1805 MA MC0 1845 2095 137 498 438 63 424 364 1925 322 MO 1845 2095 72 432 397 74 433 398 1806 MS 1845 2095 107 471 423 69 434 385 1888 MA MC0 1845 2095 143 520 457 66 443 380 200...

Страница 9: ...lectrode nozzle Control device On off signal Burner fan EVP pilot light flame EV1 1st electromagnetic valve gas EV2 2nd electromagnetic valve gas A B C D E F Operation of the air gas premix The air an...

Страница 10: ...imit the power supplied by the burner This avoids the stratification of the hot air masses and that the outlet air temperature exceeds a maximum safety level 55 C by default which will cause the burne...

Страница 11: ...or the modulation are outside the range Failure in the fan motor F4 F5 F6 Unused F7 No serial communication The remote control is disconnected F8 The flame control device does not work The flame contr...

Страница 12: ...utomatic reactivation It is installed in the auxiliary electric panel Anti fire safety device This safety device integrated in the control shuts down the unit if the probe located in the return detect...

Страница 13: ...ces etc refer to The information supplied in this document table of technical characteristics Data plate The wiring diagram and the legend supplied with the unit The CARRIERrtc electronic control broc...

Страница 14: ...burns Note The gas burner chimney is not supplied with the unit Its design and installation is the responsibility of the engineer and must comply with all the directives and regulations in force in t...

Страница 15: ...ibration transmission Air ducts connections Checks in the axial fans Before commissioning check the blade rotation direction and that the axis turns without strokes nor vibrations Once running check t...

Страница 16: ...Condensates outlet Before commissioning check the blade rotation direction and that the axis turns without strokes nor vibrations Once running check the operation conditions pressures flows and consum...

Страница 17: ...unit and all the components used This will be very helpful for maintenance and repairs to the installation Check that the electrical power supply matches the unit voltage and that its value lies with...

Страница 18: ...means this has to be taken into account in the selection of higher pressure fans optional or in the substitution of the standard pulley set with a new set that generates a higher turn speed to the pa...

Страница 19: ...ually Depending on the installation conditions the filter aspect must be examined to define the cleaning periodicity Gravimetric filters Cleaning the filtering mesh can be done with a household vacuum...

Страница 20: ...f the charge Note Both the oil type as well as the volume needed for each model are stated in the Technical characteristic tables in chapter 3 Caution Before starting any maintenance operations ensure...

Страница 21: ...n Burner Safety Devices Open the valve unblock the control and check that the burner is operating correctly 8 The safety thermostat and the air differential pressostat With the burner in operation ope...

Страница 22: ...rature of air or water in condenser very low air or water flow very high adjust flow f Repair Compressor does not start does not make noise humming a No power b The contacts of a control element are o...

Страница 23: ......

Страница 24: ...Order No 10051 03 2015 Supersedes order No New Manufactured for CARRIER in Spain The manufacturer reserves the right to change the specification without prior notice Printed in the European Union...

Отзывы: