DOWNFLOW INSTALLATIONS
To convert units for downflow applications, refer to Installation
Instructions supplied with kit for proper installation. For 40FKA
unit size 003, use kit Part No. KFADC0201SLP. For 40FKA unit
sizes 002, 005, and 006 use kit Part No. KFADC0401ACL. Use
fireproof resilient gasket, 1/8- to 1/4-in. thick, between duct, unit,
and floor.
MANUFACTURED AND MOBILE HOME HOUSING
APLICATIONS
1. Fan coil unit must be secured to the structure using field-
supplied hardware.
2. Allow a minimum of 24” clearance from access panels.
3. Recommended method of securing for typical applications
a. If fan coil is away from wall, attach pipe strap to top of fan
coil using No. 10 self tapping screws. Angle strap down
Fig. 4—Slope Coil in Horizontal-Left Application (Factory Ready)
A00096
UNIT
FIELD
SUPPLIED
HANGING
STRAPS
LOW VOLT
ENTRY
OPTIONS
POWER
ENTRY OPTIONS
SECONDARY
DRAIN
002-005 21-IN.
006 24-IN.
FRONT SERVICE
CLEARANCE
(FULL FACE
OF UNIT)
SECONDARY
DRAIN
A-COIL
HORIZONTAL LEFT
PRIMARY
DRAIN
PRIMARY
DRAIN
1 3/4 IN.
FILTER ACCESS
CLEARANCE
Fig. 5—Slope Coil in Horizontal Right Application
A02002
COIL MOUNTING
SCREW
BLOWER
ASSEMBLY
REFRIGERANT
CONNECTIONS
SECONDARY DRAIN
OVERFLOW HOLE
PRIMARY DRAIN
DRAINPAN
SLOPE COIL
SKI
COIL
SUPPORT
RAIL
4
→
→