Table 1 — Component Description
39T (Horizontal) and (Vertical)
Unit Components
COMPONENT
DESCRIPTION
UNIT SIZE
AVAILABILITY
ACC1
Access (upstream location)
07-92
AFS3
Airfoil Fan, Horizontal
Draw-Thru
07-92
AFS4
Airfoil Fan, Vertical
Draw-Thru
07-92
AFS5
Airfoil Fan, Blow-Thru
07-92
AMX1
Air Mixer
07-92
ANG1
Angle Filter
07-92
BCC2
Bypass Cooling Coil
(no damper)
B 07-92
BCF1
Bag/Cartridge Filter
(upstream location, 2-in.
prefilters)
07-92
BPH1
Bypass Heating Coil
(no damper)
B 07-92
EHS1
Electric Heating Coil
M 07-92
FBC1
Bypass Cooling Coil (with
damper)
B 07-92 (*as is)
FBH1
Bypass Heating Coil (with
damper)
B 07-92 (*as is)
FBH2
Bypass Heating Coil
(extended length with
damper)
B 07-92
FCS3
Forward-Curved Fan
(horizontal draw-thru)
07-61
FCS4
Forward-Curved Fan
(vertical draw-thru)
07-61
FCS5
Forward-Curved Fan
(blow-thru)
07-61
FLT1
Flat Filter
07-92
FMB1
Combination Filter Mixing Box
(top and rear inlet, standard
dampers)
07-92
FMB2
Combination Filter Mixing Box
(bottom and rear inlet, stand-
ard dampers)
07-92
FMB3
Combination Filter Mixing Box
(top and rear inlet, premium
dampers)
07-92
FMB4
Combination Filter Mixing Box
(bottom and rear inlet, pre-
mium dampers)
07-92
LCS1
Large Cooling Coil
L 07-92
MCS1
Medium Cooling Coil
M 07-92
MHS1
Medium Heating Coil
L 07-26 M 32-92
MXB1
Mixing Box (top and rear
inlet, standard dampers)
07-92
MXB5
Mixing Box (top and rear
inlet, for use with EXB1,
standard dampers)
07-92
MXB6
Mixing Box (top and rear
inlet, premium dampers)
07-92
MXB7
Mixing Box (top and rear
inlet, for use with EXB2, pre-
mium dampers)
07-92
PAF3
Plenum Fan (draw-thru)
11-92
VCS1
Vertical Cooling Coil
L 07-61
VCS2
Vertical Cooling/Heating Coil
L 13-26 M 32-61
VCS3
Vertical Heating/Cooling Coil
L 13-26 M 32-61
39T Return Fan Components
COMPONENT
DESCRIPTION
UNIT SIZE
AVAILABILITY
EXB1
Exhaust Box (standard
dampers)
07-92
EXB2
Exhaust Box (premium
dampers)
07-92
RAF2
Return-Air Airfoil Fan
07-92
RFC2
Return-Air Forward-Curved
Fan
07-61
39T Blow-Thru Components
COMPONENT
DESCRIPTION
UNIT SIZE
AVAILABILITY
BCF3
Bag/Cartridge Filter
(downstream location, 2-in.
prefilters)
07-92
BCS1
Blow-Thru Cooling/Heating
Coil (front discharge)
L/S 07-26
M/S 32-92
BCS2
Blow-Thru Cooling/Heating
Coil (top discharge)
L/S 07-26
M/S 32-92
BCS3
Blow-Thru Cooling Coil
(front discharge)
L 07-26
M 32-92
BCS4
Blow-Thru Cooling Coil
(top discharge)
L 07-26
M 32-92
BCS7
Blow-Thru Cooling Coil (full
front discharge, downstream
components)
L 07-26
M 32-92
ACC2
Access
07-92
PAF5
Plenum Fan (blow-thru)
11-92
ZDS1
Zone Damper
07-92
LEGEND
B — Bypass Coils
L
— Large Face Area
M — Medium Face Area
S — Small Face Area
*Accommodates bypass size chilled water coil. No bypass size direct
expansion coils are available.
NOTES:
1. First coil type is upstream coil, cold deck coil in BCS1 or 2.
2. Second coil type is downstream, hot deck coil in BCS1 or 2.
3. Coil sections may be ordered less coils.
4. First coil/second coil type.
3
Содержание 39T
Страница 43: ...Fig 34 Discharge Fabrication Draw Thru Plenum Fans 43 ...
Страница 49: ...Fig 41 Coil Connections and Lifting Points Fig 42 Steam Coil PIping 49 ...
Страница 78: ...Fig 64 Blow Thru Unit Coil Removal Fig 65 Plan View Typical Coil 78 ...
Страница 81: ...Fig 68 Filter Arrangement 2 in and 4 in Flat 81 ...
Страница 82: ...Fig 68 Filter Arrangement 2 in and 4 in Flat cont 82 ...
Страница 83: ...Fig 69 Filter Arrangement Angle Filters 2 in Only 83 ...
Страница 84: ...Fig 69 Filter Arrangement Angle Filters 2 in Only cont 84 ...
Страница 85: ...Fig 70 Filter Arrangement BCF1 Bag or Cartridge Draw Thru 85 ...
Страница 86: ...Fig 70 Filter Arrangement BCF1 Bag or Cartridge Draw Thru cont 86 ...
Страница 87: ...Fig 71 Filter Arrangement BCF3 Bag or Cartridge Blow Thru 87 ...
Страница 88: ...Fig 71 Filter Arrangement BCF3 Bag or Cartridge Blow Thru cont 88 ...
Страница 92: ...NOTE A frame shown shaded Fig 74 Fan Discharge Positions 92 ...
Страница 102: ......
Страница 103: ......