08
07
Installing, starting up, and servicing air-conditioning equipment can be hazardous due to system ressures,
electrical components, and equipment location (roofs, elevated structures, etc.).
Only trained, qualified installers and service mechanics should install, start-up, and serve this equipment.
When working on the equipment, observe precautions in the literature and on tags, stickers, and labels attached
to the equipment.
Follow all safety codes. Wear safety glasses and work gloves. Keep quenching cloth and fire extinguisher
nearby when brazing. Use care in handing, rigging, and setting bulky equipment.
Read these instructions thoroughly and follow all warnings or cautions included in literature and attached to the
unit. Consult local building codes and National Electrical Code for special requirement.
Note:
The installation plate is fixed with a screw for the conve-
nience of shipment, please remove the screw first before
installation. (see figure)
The mounting plate will look like one of the figure
depending on the unit size.
The holes for fixing anchors should be 5mm.
Screw
Step 1: Determine Wall Hole Position
Step 2: Attach Mounting Plate
Step 3: Drill Wall Hole
Fix the mounting plate horizontally and level on the wall with five
or more A-type screws.
Install The Mounting Plate
Drill Hole In The Wall
Indoor
Wall
Outdoor
5-7mm
Step 4: Connect Pipe
L
N
S
Step 5: Connect Wire
Step 6: Prepare Drain Hose
STEP
8
Indoor Wire Connection
1. Lift the indoor unit front panel.
2. Open the indoor unit electrical cover with a screwdriver
through the hole, remove the terminal block cover by
hand and remove the cable clamp by loosening the
screws
3. Pass the connecting wires from the back of indoor unit
and connect to the indoor terminal block.
Front panel
The drain line must not have a trap anywhere in
its length, must pitch downwards, and must be
insulated up to the outside wall.
Drainage
Do not put drain end into water
Proper
Do not form a rise
Step 7: Wrap Pipe and Cable
Step 8: Hang the Indoor Unit
1. Run refrigerant lines through hole in the wall.
2. Hang indoor unit on upper hook of mounting plate,
then push lower part of indoor unit up on wall to lower
hook.
3. Move indoor unit from side to side, up and down to
check if it is hooked securely.
Hang The Indoor Unit
For proper orientation of the refrigerant piping,
electrical cable and drain lines, refer to below Fig:
- Place the drain hose below the refrigerant piping.
- Make sure that the drain hose is not heaved or
snaked.
Wrap The Pipe
Indoor unit
Electrical
cable
Drain hose
Heat insulation
type
Refrigerant piping
Pipe room
Ponding box
2.1 INDOOR UNIT MOUNTIN PLATE
2.2 INSTALLATION PROCESS
2. INDOOR UNIT INSTALLATION
2
.
INDOOR UNIT INSTALLATION
Electrical cover
Open the cover
from this hole
Connector for wired controller
(optional,come out from display box)
30
Wedge
Drill a 65mm or 90mm(depending on
models) hole on the wall which is
slightly tilted towards the outside.
The connector parts of connective pipe must
be placed outside of room.
CAUTION
Indoor unit
outline
895
435
435.5
217
460
242.5
45
150
258
wall hole
65
232.5
45
45
wall hole
65
298
Unit: mm
Note: When the gas side connective pipe is Ф16mm(5/8in) or more, the pipe hole should be 90mm(3.54in).
Wire box cover
Screw
Screw
Terminal block
cover
Cable clamp
GB
Содержание 38QHP009E8S
Страница 14: ...1 05 1 06 15cm 30cm 2 3m 200cm 60cm 30cm 60cm 12cm 12cm 1 2 3 1 1 2 1 1 1 B 2 5 1 A 5 N 1 3 2 3 m BG...
Страница 15: ...07 2 2 1 65 65 mm 5 mm 2 2 A 65 mm 90 mm 1 2 3 4 8 1 2 3 5 6 7 1 2 3 08 2 16 mm 5 8 in 90 mm 3 54 in BG...
Страница 20: ...17 7 7 12 7 13 7 14 25 7 15 18 7 7 9 7 10 10 1 10 2 7 11 BG...
Страница 21: ...19 7 20 7 19 7 20 1 2 3 4 5 7 7 16 7 17 80 7 18 BG...
Страница 50: ...17 7 7 12 7 13 7 14 LFL 25 OFN 7 15 OFN OFN OFN 18 7 7 9 7 10 10 1 10 2 7 11 EL...
Страница 51: ...19 7 20 7 19 7 20 1 2 3 4 5 7 7 16 OFN 7 17 80 7 18 EL...