GB - 7
NTC
E N G L I S H
Item
Value
Description
Displayed
AQUASMART
MAESTRO
4-
NO
Available
Available
[Default: 22°C: 72°F]
5-
Available
Available
[Default: “0,5” °C: “1” °F]
6-
7-
Not Available
Set point value
15,16,17,18,19,20,21,
22,23,24,25,26,27,28,
29,30,31,32 °C
59,60,61,62,63,64,65,
66,67,68,69,70,71,72,
73,74,75,76,77,78,79,
80,81,82,83,84,85,86,
87,88,89,90 °F
Reset step value
0;0.5;1;1.5;2 °C
0;1;2;3;4 °F
YES:
If the reset step value is set to
0, the stand alone mode is not
available. The IR remote control
and its display, work as in
communicating mode
Fixed speed
Variable fan speed
[Default: “F” 3 fixed speeds]
NO
In case of variable fan, the icons
available are two: HIGH speed
and AUTO mode
Fixed speed
available
Variable fan
speed
available
Fan speed type
F
U
Blind groups available
0
1
...
4
5
There is no blind/groups to control:
no icons will be displayed
Just one blind group is available: “1”
group icons will be illuminated
…
Four blinds groups are available:
“blind” and “4” groups icons will be
illuminated in the blind menu
There is no group, but user can
manage the blind
[Defaults: “0”: Blinds control disabled]
YES
Once the blind menu is selected,
the groups icon will be
energized on the lcd (no icons if
just one group is selected)
“A” and “1” icons are energized
in the blind menu. User can
manage all blinds or just one
Available in
conjunction
with Power
Module
8-
Not Available
9-
Not Available
10-
Available
Not Available
Blind Inclination
No
Ye
The installed blinds doesn’t have the
capability to modify its inclination
The installed blinds has the motor
able to change its inclination
[Default: “No” Blinds doesn’t have
the capability to change its
inclination]
NO
The blind inclination feature
becomes active into the Blind
Menu. No icon point out this
feature out of the blind menu
Available in
conjunction
with Power
Module
Lights groups available
0
1
….
4
5
There is no lights/groups to control:
no icons will be displayed
Just one lights group is available: “1”
group icons will be illuminated
…
Four lights groups are available:
“Lamp” and “4” groups icons will be
illuminated
There is no group, but user can
manage the light
[Defaults: “0” Lights control
disabled.]
YES
Once the Lights Menu is
selected, the groups icon will be
energized on the lcd (no icons if
just one group is selected)
“A” and “1” icons are energized
in the light menu. User can
manage all lights or just one
Available in
conjunction
with Power
Module
Louver presence
No
Ye
Some units doesn’t have the louver
installed. This item consents to
don’t show the louver icon on the
LCD
None
Louver installed (Stepper motor or
Synchronous motor + home
position) Fbattery
[Defaults: “No” No louver presence.]
YES
This icon will show on the LCD
the functioning of the louver
NTC system configuration