For the high pressure single and dual-pump motors of 30RB/RBP 170R-950R units (options 116R, 116S, 116V, 116W)
No.
(2)
Description
(3)
170R 190R 210R 230R 270R 310R 340R 380R 410R 450R
1
Nominal efficiency at full load and nominal voltage
%
87,5 87,5 87,5 87,5 89,6 89,6 89,7 89,7 89,7 90,8
1
Nominal efficiency at 75% of full load and nominal voltage
%
88,2 88,2 88,2 88,2 90,4 90,4 90
90
90 90,8
1
Nominal efficiency at 50% of full load and nominal voltage
%
87,5 87,5 87,5 87,5 89,9 89,9 89
89
89 89,6
2
Efficiency level
-
IE3
3
Year of manufacture
-
This information varies depending on the manufacturer and
model at the time of incorporation. Please refer to the motor
name plates,
4
Manufacturer's name and trademark, commercial registration
number and head office of manufacturer
-
Same as above
5
Product model number
-
Same as above
6
Number of motor poles
-
2
7-1
Nominal shaft power output at full load and nominal voltage (400 V)
kW
3
3
3
3
4
4
5,5
5,5
5,5
7,5
7-2
Maximum input power (400 V)
(4)
kW
3,44 3,44 3,44 3,44 4,49 4,49 6,17 6,17 6,17 8,32
8
Nominal input frequency
Hz
50
9-1
Nominal voltage
V
3 x 400
9-2
Maximum current drawn (400 V)
(5)
A
6,33 6,33 6,33 6,33 7,75 7,75 10,40 10,40 10,40 14,10
10
Nominal speed
r/s -
rpm
48 - 2900
11
Product disassembly, recycling or disposal at end of life
-
Disassembly using standard tools. Disposal and recycling using
an appropriate company
12
Operating conditions for which the motor is specifically designed
I - Altitudes above sea level
m
< 1000
(6)
II - Ambient air temperature
°C
< 40
III - Maximum operating temperature
°C
Please refer to the operating conditions given in this manual or
in the specific conditions given in the selection programs.
IV - Potentially explosive atmospheres
-
Non ATEX environment
No.
(2)
Description
(3)
480R 550R 610R 670R 720R 770R 820R 870R 950R
1
Nominal efficiency at full load and nominal voltage
%
90,8 90,8 91,6 91,6 91,6 93,1 93,1 93,1 93,1
1
Nominal efficiency at 75% of full load and nominal voltage
%
90,8 90,8 92,2 92,2 92,2 93,3 93,3 93,3 93,3
1
Nominal efficiency at 50% of full load and nominal voltage
%
89,6 89,6 91,7 91,7 91,7 92,7 92,7 92,7 92,7
2
Efficiency level
-
IE3
3
Year of manufacture
-
This information varies depending on the manufacturer and
model at the time of incorporation. Please refer to the motor
name plates,
4
Manufacturer's name and trademark, commercial registration number
and head office of manufacturer
-
Same as above
5
Product model number
-
Same as above
6
Number of motor poles
-
2
7-1
Nominal shaft power output at full load and nominal voltage (400 V)
kW
7,5
7,5
11
11
11
15
15
15
15
7-2
Maximum input power (400 V)
(4)
kW
8,32 8,32 12,00 12,00 12,00 16,20 16,20 16,20 16,20
8
Nominal input frequency
Hz
50
9-1
Nominal voltage
V
3 x 400
9-2
Maximum current drawn (400 V)
(5)
A
14,10 14,10 20,20 20,20 20,20 26,60 26,60 26,60 26,60
10
Nominal speed
r/s -
rpm
48 - 2900
11
Product disassembly, recycling or disposal at end of life
-
Disassembly using standard tools. Disposal and recycling using
an appropriate company
12
Operating conditions for which the motor is specifically designed
I - Altitudes above sea level
m
< 1000
(6)
II - Ambient air temperature
°C
< 40
III - Maximum operating temperature
°C
Please refer to the operating conditions given in this manual or
in the specific conditions given in the selection programs.
IV - Potentially explosive atmospheres
-
Non ATEX environment
(1) Required by regulation No. 2019/1781 concerning the application of directive 2009/125/EC on the ecodesign requirements for electric motors.
(2) Item number imposed by regulation No. 2019/1781, annex I2b.
(3) Description given by regulation No. 2019/1781, annex I2b.
(4) To obtain the maximum input power for a unit with a hydraulic module, add the “maximum operating input power” for the unit (see Electrical data table) to the
pump power.
(5) To obtain the maximum operating intensity for a unit with a hydraulic module, add the “maximum operating intensity” for the unit (see Electrical data table) to the
pump intensity.
(6) Above 1000 m, a degradation of 3% for each 500 m should be taken into consideration.