For the low pressure single pump motors of 30RQ/RQP 165-520R units (option 116T)
No.
(2)
Description
(3)
165R 180R 210R 230R 270R 310R 330R 370R 400R 430R 470R 520R
1
Nominal efficiency at full load and nominal voltage
%
86,4 86,4 86,4 86,4 86,4 87,5 89,6 89,6 89,6 89,6 89,7 89,7
1
Nominal efficiency at 75% of full load and nominal voltage
%
86,9 86,9 86,9 86,9 86,9 88,2 90,4 90,4 90,4 90,4 90
90
1
Nominal efficiency at 50% of full load and nominal voltage
%
85,7 85,7 85,7 85,7 85,7 87,5 89,9 89,9 89,9 89,9 89
89
2
Efficiency level
-
IE3
3
Year of manufacture
-
This information varies depending on the manufacturer and model at
the time of incorporation. Please refer to the motor name plates,
4
Manufacturer's name and trademark, commercial registration
number and head office of manufacturer
-
Same as above
5
Product model number
-
Same as above
6
Number of motor poles
-
2
7-1 Nominal shaft power output at full load and nominal voltage
(400 V)
kW
2,2 2,2 2,2 2,2 2,2
3
4
4
4
4
5,5 5,5
7-2
Maximum input power (400 V)
(4)
kW
2,53 2,53 2,53 2,53 2,53 3,44 4,49 4,49 4,49 4,49 6,17 6,17
8
Nominal input frequency
Hz
50
9-1 Nominal voltage
V
3 x 400
9-2
Maximum current drawn (400 V)
(5)
A
4,56 4,56 4,56 4,56 4,56 6,33 7,75 7,75 7,75 7,75 10,40 10,40
10
Nominal speed
r/s -
rpm
48 - 2900
11
Product disassembly, recycling or disposal at end of life
-
Disassembly using standard tools. Disposal and recycling using an
appropriate company
12
Operating conditions for which the motor is specifically designed
I - Altitudes above sea level
m
< 1000
(6)
II - Ambient air temperature
°C
< 40
III - Maximum operating temperature
°C
Please refer to the operating conditions given in this manual or in the
specific conditions given in the selection programs.
IV - Potentially explosive atmospheres
-
Non ATEX environment
For the low pressure dual pump motors of 30RQ/RQP 165-520R units (option 116U)
No.
(2)
Description
(3)
165R 180R 210R 230R 270R 310R 330R 370R 400R 430R 470R 520R
1
Nominal efficiency at full load and nominal voltage
%
85,9 86,4 87,5 87,5 87,5 87,5 89,6 89,6 89,6 89,6 89,7 89,7
1
Nominal efficiency at 75% of full load and nominal voltage
%
86,4 86,9 88,2 88,2 88,2 88,2 90,4 90,4 90,4 90,4 90
90
1
Nominal efficiency at 50% of full load and nominal voltage
%
84,9 85,7 87,5 87,5 87,5 87,5 89,9 89,9 89,9 89,9 89
89
2
Efficiency level
-
IE3
3
Year of manufacture
-
This information varies depending on the manufacturer and model at
the time of incorporation. Please refer to the motor name plates,
4
Manufacturer's name and trademark, commercial registration
number and head office of manufacturer
-
Same as above
5
Product model number
-
Same as above
6
Number of motor poles
-
2
7-1 Nominal shaft power output at full load and nominal voltage
(400 V)
kW
1,5 2,2
3
3
3
3
4
4
4
4
5,5 5,5
7-2
Maximum input power (400 V)
(4)
kW
1,76 2,53 3,44 3,44 3,44 3,44 4,49 4,49 4,49 4,49 6,17 6,17
8
Nominal input frequency
Hz
50
9-1 Nominal voltage
V
3 x 400
9-2
Maximum current drawn (400 V)
(5)
A
3,17 4,56 6,33 6,33 6,33 6,33 7,75 7,75 7,75 7,75 10,40 10,40
10
Nominal speed
r/s -
rpm
48 - 2900
11
Product disassembly, recycling or disposal at end of life
-
Disassembly using standard tools. Disposal and recycling using an
appropriate company
12
Operating conditions for which the motor is specifically designed
I - Altitudes above sea level
m
< 1000
(6)
II - Ambient air temperature
°C
< 40
III - Maximum operating temperature
°C
Please refer to the operating conditions given in this manual or in the
specific conditions given in the selection programs.
IV - Potentially explosive atmospheres
-
Non ATEX environment
(1) Required by regulation No. 2019/1781 concerning the application of directive 2009/125/EC on the ecodesign requirements for electric motors.
(2) Item number imposed by regulation No. 2019/1781, annex I2b.
(3) Description given by regulation No. 2019/1781, annex I2b.
(4) To obtain the maximum input power for a unit with a hydraulic module, add the “maximum operating input power” for the unit (see Electrical data table) to the
pump power.
(5) To obtain the maximum operating intensity for a unit with a hydraulic module, add the “maximum operating intensity” for the unit (see Electrical data table) to the
pump intensity.
(6) Above 1000 m, a degradation of 3% for each 500 m should be taken into consideration.
5 - PHYSICAL AND ELECTRICAL DATA FOR THE UNITS
21