![Carrier Access BROADway System 770-0125-AB Скачать руководство пользователя страница 74](http://html1.mh-extra.com/html/carrier-access/broadway-system-770-0125-ab/broadway-system-770-0125-ab_installation-manual_2564210074.webp)
3-26
BROADway - Release 4.00
Configuration
Managing the BROADway Configuration Database
To
delete
an
OFFLINE
database, use the
DLT-DB
TL1 command:
DLT-DB::NSP:1234::<name>;
<name>
—User defined
OFFLINE
database name.
Examples:
Delete the database called
offlinename
from the active NSP:
DLT-DB::NSP:1234::offlinename;
Delete the database called
offlinename
from NSP-1:
DLT-DB::NSP-1:1234::offlinename;
Deletes the database called
offlinename
from NSP-2:
DLT-DB::NSP-2:1234::offlinename;
You cannot delete the database that is either currently stored as
RUNNING
or
SAVED
.
To
initialize
the database system to its factory default, use the
INIT-DB
TL1 command:
INIT-DB::NSP:1234;
After you initialize the database, reboot the
BROAD
way system using the
INIT-SYS
TL1 command
(see page 3-27).
CAUTION!
U
SE
THE
INIT-DB
COMMAND
WITH
EXTREME
CARE
AS
IT
WILL
RESET
THE
SAVED
CONFIGURATION
DATABASE
TO
A
FACTORY
DEFAULT
STATE
. E
NSURE
YOU
HAVE
A
BACKUP
OF
ANY
PREVIOUS
SAVED
CONFIGURATION
BEFORE
YOU
EXECUTE
THIS
COMMAND
.
Exporting the BROADway Database to a TL1 Script
The
BROAD
way embedded database is designed to offer fast access to each configuration element of
the
BROAD
way switch. However, it is not stored in a simple human-readable format. To dump the
contents of the database to a TL1 script format, the following TL1 commands can be used:
EXEC-SYS::NSP:1234::cfgDumpTL1;
EXEC-SYS::NSP:1234::cfgDumpTL1verbose;
The
EXEC-SYS
command accesses each element configuration table within the database in turn and
converts the contents to a series of TL1 commands. The first variant of the command will only print
information that is changed from the default switch settings. The second variant of the command will
print the entire database as a series of TL1 commands.
In this release of the system software, the output is sent to the console from which the command was
executed, i.e. the serial craft port or a Telnet session. An operator using a terminal emulation program
such as Hyperstream can capture the output from the switch to a file on the local PC, and replay it back
to the switch to configure the product.
It is also possible to capture the output, modify certain script parameters and then play it back to
replicate a single configuration easily on multiple
BROAD
way switches.
Содержание BROADway System 770-0125-AB
Страница 1: ...BROADway INSTALLATION MANUAL Part Number 770 0125 AB Product Release 4 00 March 2004 ...
Страница 10: ...x BROADway Release 4 00 Preface Third Party Software Notices ...
Страница 14: ...xiv BROADway Release 4 00 Table of Contents ...
Страница 15: ...CHAPTER 1 Introduction In This Chapter Overview ...
Страница 59: ...BROADway Release 4 00 3 11 Configuration Logging In With the Web Browser Interface GUI ...
Страница 96: ...Index 4 BROADway Release 4 00 Index V ...