BROADway - Release 4.00
3-19
Configuration
Setting the System Date and Time
Setting the System Date and Time
The
BROAD
way system maintains a real-time clock to assist in ensuring event and alarm times are
properly recorded in the system. This section describes how to set the real-time clock from the GUI and
command line interfaces.
Setting the Date and Time Using the GUI
To set the date and time on the
BROAD
way system:
1. In the menu bar, click
Config
, then
Date &
Time
.
2. In the
Date & Time
window, enter the date
and time.
-
To set the
BROAD
way system to the
same date and time as your workstation,
click
Set to Today
.
-
Alternately, enter the date and time you
require using the
Year
,
Month
,
Day
,
Hour
, and
Minute
fields.
3. Click
OK
.
Setting the Date and Time Using TL1
To
view
the system date and time, use the
RTRV-DAT
TL1 command:
RTRV-DAT::NSP:1234::;
To
change
the system date and time, use the
ED-DAT
command:
ED-DAT::NSP:1234::YY-MM-DD,HH-MM-SS;
YY-MM-DD
—The two-digit year, month, and day of the system date.
HH-MM-SS
—The time (24-hour clock) of the system.
For example:
ED-DAT::NSP:1234::03-07-01,15-35-00;
This command changes the date to July 1, 2003 and the time to 3:35 PM.
Содержание BROADway System 770-0125-AB
Страница 1: ...BROADway INSTALLATION MANUAL Part Number 770 0125 AB Product Release 4 00 March 2004 ...
Страница 10: ...x BROADway Release 4 00 Preface Third Party Software Notices ...
Страница 14: ...xiv BROADway Release 4 00 Table of Contents ...
Страница 15: ...CHAPTER 1 Introduction In This Chapter Overview ...
Страница 59: ...BROADway Release 4 00 3 11 Configuration Logging In With the Web Browser Interface GUI ...
Страница 96: ...Index 4 BROADway Release 4 00 Index V ...