BROADway - Release 4.00
2-23
Installation
Installing the BSP200 Line Interface Card
If the card failure sequence is displayed, remove the card and re-insert it into the chassis. If the card
failure sequence is still displayed, then replace the card.
Line status (per port):
INTERFACE Red LED
(Bottom)
INTERFACE Green
LED (Top)
Status
Off
Off
The card is not configured, or
alarm reporting is disabled on the
interface
Off
On
Interface operating normally
Off
Blinking
Interface performing a diagnostic
test
On
Off
Interface failure (LOS, OOF, AIS)
Blinking
Off
Yellow alarm (RAI)
On
On
Interface initializing during system
power up