35
3.
Enter the theoretical weight that was noted from the INFO screen in step 1 and
press CONFIRM twice.
4.
Enter the weight actually sowed and press CONFIRM twice.
5.
The calibration factor is recalculated, and the error % and the maximum
forward speed (fig. 18) are also displayed. Press CONFIRM again to confirm
the new factor.
B.9 Setting the turbine speed and hopper empty alarms
To see the alarm thresholds (fig. 19), from the SETTINGS screen, press
.
Figure 19
To adjust the thresholds, enter the value and press CONFIRM.
B.10 Simulating forward speed
If the forward speed sensor (radar, encoder on a wheel, etc.) is no longer
working, you can continue sowing by simulating a forward speed. What is important
is to remember what your forward speed was before the breakdown, in order to
type the right simulation speed, otherwise the sowing density will not be correct. If
you sow at a speed that is higher than the simulation speed, you will under-dose
and vice-versa.
To set the simulated forward speed, from the SETTINGS screen, select ‘1
Operator Config’ then ‘2. Speed sensor factor’.
Press
(fig. 20), then enter the value of the simulation speed (fig. 21).
Press the CONFIRM button to start the speed simulation.
Figure 20
During the speed simulation, the forward speed on the MAIN screen blinks (fig. 22)
Low turbine speed alarm
High turbine speed alarm
Hopper empty alarm (ON/OFF)