25
The console has a special mode in order to easily CALIBRATE the dispenser.
In this CALIBRATION mode, each dispenser is controlled by the "manual calibration
button" to distribute the product (figure 1).
During normal operation, the system is automatically started and stopped by a
magnetic sensor when the sower is raised and lowered for work. According to the
type of installation, this sensor is actuated either by the movement of a wheel or by
the markers.
A.3
Data Regulation and Recording Modes
Automatic Regulation Mode
The sowing dose is automatically adjusted according to the forward speed, in
order to ensure that the current sowing dose constantly corresponds to the preset
target dose. The sowing dose can be increased or decreased manually in relation
to the preset target dose.
Parcel plan data ("work summary") can be recorded and stored in the console's
internal memory. Up to 75 summaries can be stored. With a GPS receiver and an
SD memory card, you can also record the vehicle's travel and the application data
in a "Dynamic record" file on the SD card. The work summary is also created in this
file.
Regulation Mode with Dose Modulation
This allows the system to be controlled by preset cards (prepared using high-
precision farming software and the position provided by the DGPS). In order to
carry out automatic dose modulation, the
PS 8000i
requires a DGPS receiver and an
SD memory card in order to load the preset plans generated with high-precision
farming software.
A work record file is automatically created in the card for recording the data
which confirms the current application. The work summary is also created in this
file, and it can be opened in high-precision farming software.
A.4 Psi console buttons
All of the console functions are available through 9 buttons located at the edge
of the LCD screen.
Figure 1
Menu Buttons
Sub-menu Buttons
Confirm
Delete
SD card reader
On-Off Button