Ethernet
Machine Control Connectors
DCTM / Machine Control Port Pinout
Note:
The Tally, Tach, and Direction inputs are bridge rectified and current limited.
Min. Input Voltage: 5V. Max. Input Voltage: 40V. Typical Input Current: 10mA.
DCTM LTC and MTC Connector Pinout
MIDI Connector Pinout
49
7.7.99
Connector Summary
SL 9000 J Series
5-Pin DIN-Type MIDI Sockets
Pin
Function
1
n/c
2
Gnd. (Shield)
3
n/c
4
MIDI +
5
MIDI -
SL 9000 J Series
25-Pin 'D'-Type 'TIME CODE' Socket
Pin
Function
Pin
Function
Pin
Function
Pin
Function
Pin
Function
1
In 1 +
6
In 4 -
11
Out 3 -
16
In 2 Gnd.
21
Out 1 Gnd.
2
In 1 Gnd.
7
n/c
12
Out 4 +
17
In 3 -
22
Out 2 -
3
In 2 -
8
Out 1 -
13
Out 4 Gnd. 18
In 4 +
23
Out 3 +
4
In 3 +
9
Out 2 +
14
In 1 -
19
In 4 Gnd.
24
Out 3 Gnd.
5
In 3 Gnd.
10
Out 2 Gnd. 15
In 2 +
20
Out 1 +
25
Out 4 -
SL 9000 J Series
25-Pin 'D'-Type 'MACHINE CONTROL' Socket
Pin
Function
Pin
Function
Pin
Function
Pin
Function
Pin
Function
1
n/c
6
PLAY Sw.
11
n/c
16
REW Tally 21
REC TAlly
2
Tally Com. 7
REV Sw.
12
n/c
17
FF Tally
22
TACH IN 2
3
REW Sw.
8
REC Sw.
13
n/c
18
STOP Tally 23
DIR 2
4
FF Sw.
9
TACH IN 1 14
n/c
19
PLAY Tally 24
n/c
5
STOP Sw.
10
DIR 1
15
Sw. Com.
20
REV Tally
25
n/c
RJ45/10baseT ‘NETWORK’ Sockets
Pin
Function
Pin
Function
1
Tx Data +
5
HOT
2
Tx Data -
6
Rx Data -
3
Rx Data +
7
0V
†
4
COLD
8
+12V
†
NOTE
†: Pins 7 and 8 are not
connected on the
‘PORT 6’ sockets on
the console, processor,
and Hub Router.
Cable Connections
Tx Data +
Tx Data -
Rx Data +
Rx Data -
COLD
HOT
0V
+12V
Tx Data +
Tx Data -
Rx Data +
Rx Data -
COLD
HOT
0V
+12V
8
1
8
1
Содержание Solid State Logic SL 9000 J Series
Страница 1: ...82S6Q9K010B SL 9000 Series Installation Guide V 2 1 2 7 98...
Страница 2: ...12 3 97...
Страница 3: ...Solid State Logic SL 9000 Series Installation Guide V2 1 2 7 98...
Страница 8: ...i8 12 3 97 SL 9000 J Series Console Installation Guide...
Страница 9: ...Solid State Logic SL 9000 J Total Studio System Installation Guide 82S6Q9K010B...
Страница 44: ...36 18 9 97 SL 9000 J Series Console Installation Guide...