DC filter and smoothing
Height :
9U ‡
Max Depth :
700mm (excluding cabling)
Mounting :
Permanently mounted in base of PSU rack.
Weight :
200kg approximate
Voltage :
The filter unit is Passive
Cooling :
Front-to-back fan assisted. Allow adequate clearance for
exhaust.
Air filter :
2 part filters mounted onto clip-on trim door. Periodic changing
is required to ensure correct airflow.
‡
The DC filter unit is normally fixed into the base of the Power Supply 39U rack. If
you require alternative fixing, this must be arranged prior to start of console build.
NOTE
Due to the size of the Harting Han K connectors, ensure clear access
to the rear of the rack - a minimum clearance of 12” (305mm) is recommended.
Power Supply Supervisor
Height :
1U
Max Depth :
350mm (excluding cabling)
Mounting :
Rack mounted shelves
Weight :
8kg approximate
Voltage :
100-120 VAC/220-240 VAC, selectable at the back panel
Power :
150W approx.
AC Power
One IEC inlet located under centre section.
DC Power
2 or 4 (depending on console size) Harting Han K connectors
from power supply filter unit. Max distance 15m. Supplied
with 10m cables as standard.
7
2.7.98
Specifications
Содержание Solid State Logic SL 9000 J Series
Страница 1: ...82S6Q9K010B SL 9000 Series Installation Guide V 2 1 2 7 98...
Страница 2: ...12 3 97...
Страница 3: ...Solid State Logic SL 9000 Series Installation Guide V2 1 2 7 98...
Страница 8: ...i8 12 3 97 SL 9000 J Series Console Installation Guide...
Страница 9: ...Solid State Logic SL 9000 J Total Studio System Installation Guide 82S6Q9K010B...
Страница 44: ...36 18 9 97 SL 9000 J Series Console Installation Guide...