EN
Adjust gun or reduce fluid pressure.
Thin, sandy coarse finish drying
before it flows out.
Too much fluid flow.
Runs and sags.
Increase fluid flow by changing fluid
tip size, supply pressure or turning
needle control knob counter
clockwise.
Ball end heavy
pattern.
Too much fluid flow.
Change fluid tip for smaller size or
change air cap for different
specification air cap.
Excessive bounce-back.
Too much atomisation air pressure.
Reduce air pressure.
Gun too far from surface.
Check distance (normally 150-
200mm).
Material too thin.
Mix properly or apply light
coats/reduce fluid flow.
Gun tilted at an angle.
Mount gun at right angle to work.
Gun too far from surface.
Check distance.
Too much air pressure.
Reduce air pressure and check spray
pattern.
Fluid flow too low.
SB-E-2-990 R6.0
16/24