EN
Fluid leaking between the spray
gun and the intermediate plate.
Lock cam or replace using
AGMDPRO-406-K.
Locking cam not locked or worn.
Replace.
Fluid needle external profile
damaged or worn.
When removing air cap from retaining ring, do not remove the ring seat from the retaining ring.
Damage to the parts may occur. Simply wipe parts clean and reassemble with new or clean air cap.
FLUID FAULTS
CAUSE
CORRECTION
Slow fluid leak from fluid tip and
needle seat.
Fluid tip internal seat scored
damaged or worn.
Replace.
Contamination on needle or tip
mating surfaces preventing good
seal.
Thoroughly clean.
Incorrect fluid tip for fluid needle
fitted to gun.
Check tip/needle selection chart
and fit correct item.
Sluggish needle.
Lubricate packing. (GL-1)
Tight packing nut.
Adjust.
O-Rings damaged or missing.
Replace O-Rings using
AGMDPRO-29X-K5.