CF500 cylinder repair regulations, Article No. 9305003
03-09-2008 / GB 8 of 26
Removing the G02 cartridge (load)
First, loosen the nut with which the coil has been mounted (spanner 19) and remove the coil (to ensure
that the pins and the cartridge are not damaged); figure 11.0.
Next, unscrew the cartridge from the control valve (spanner 22).
Seal the opening again using the GS021 plug, which can be found next to the test connections in the
block (spanner 24) (the code can be found on the valve); figures 12.0 and 13.0.
Figure 13.0
Figure 11.0
Figure 12.0