background image

___________________________________________________________________________ 

_____________________________________________ 

        By Carepeutic® 

17

 

 

Unplug the appliance from the electric outlet and allow it to cool down and get 
dried. 

 

Store it in its box or in a clean, dry place. 

 

Do NOT drag or hang the unit with the power cord. 

 

This appliance is designed for indoor use only. 

 

Never put the appliance close to fireplace or other heating sources.   

 

 

Correct Disposal of this product 
This marking indicates that this product should not be disposed 
with other household wastes. To prevent 
possible harm to the environment or human health from 
uncontrolled waste disposal, recycle it responsibly to promote the 
sustainable reuse of material resources. To return your used 
device, please use the return and collection systems or contact the 

retailer where the product was purchased. They can take this product for environmental safe 
recycling. 
 

Troubleshooting: 

 

Problem Cause 

Solutions 

Water Jet or 
waterfall not 
working 

Water filter and or waterfall 
valve is blocked. 

clean up the water filter if 
necessary. Check and clean up 
the herbal bag basket. 

Heating not working 
 
 
 
 
 
 

Heating function is turned off. 
It may reach the preset 
maximum water temperature. 
The adjusted highest water 
temperature may be too low. 
The current water temperature 
inside water container is 
already higher than your preset 
water temperature. 
 

Turn on Heating function. 
Press the Temp+/- to adjust the 
preset highest water 
temperature. 
 
 
 

Preset working time is up 
(max. is 50 minutes). 
 

Try to unplug the power source 
completely for a while and plug 
in the power again.   

Device stops 
working 

Auto shut off for protection 
when using too long time. 

Try to unplug the power source 
completely for a while and plug 
in the power again. 

Содержание KH298

Страница 1: ..._______________ By Carepeutic Ozone Waterfall Foot and Leg Spa Bath Massager A Tradition for Foot Reflexology Instruction Manual Model KH298 This user manual provides both operation information of this product and its detailed specifications Read this manual and understand it thoroughly before operation ...

Страница 2: ...have the gout arthritis joint deformation skin disease and allergic dermatitis have neurological disorder or perceptual disorder on skin have fractured or plastic surgery materials inside your knee joint legs or feet are unable to feel normal temperature we advise you to consult with your doctor before using this massager SAFETY NOTE Attention Never try to turn on the power or operate this device ...

Страница 3: ...prohibited to have excited exercise should not use this device unless you have consulted with your doctor People with skin allergy wounded or after surgery and not well recovered should not use this device unless you have consulted with your doctor Unauthorized person is not allowed to reconstruct or replace the component of this device Do not use this device in sauna room or bath room or in area ...

Страница 4: ...utlet 7 Use only the original adaptor that comes with the device 8 It is recommended not to use any electronic devices while using the foot spa massager avoid possibly dropping electronic devices into water container NOTICE this massager should not be used in the following cases Massage should be comfortable and pleasant Should pain or discomfort result discontinue use and consult your doctor Avoi...

Страница 5: ...ore using this device if you have diabetes as diabetes can contribute to foot problems including decreased feeling or circulation to the feet If you take foot spa everyday you should rub lotion or skin moisturizer and wear socks for keeping warm after taking foot bath ATTENTION This device is being tested with water at factory if there is any water drops left inside water container it is normal To...

Страница 6: ...___________________________________________ By Carepeutic 6 SPECIFICATIONS Default working time 50 minutes Default water drainage time 3 minutes Turn on the drainage function again if you need more time to drain out all water With 110V 60Hz power cord Power consumption 800W KH298 ...

Страница 7: ...___________________________________________________________________________ _____________________________________________ By Carepeutic 7 PRODUCT PARTS Figure 1 Figure 2 ...

Страница 8: ...___________________________________________________________________________ _____________________________________________ By Carepeutic 8 Figure 3 Figure 4 ...

Страница 9: ..._________ _____________________________________________ By Carepeutic 9 Figure 5 water drainage OPERATION INSTRUCTION NOTE You must fill in water before turning on the foot bath massager Never try to operate this device without having water inside the water container ...

Страница 10: ... Never try to operate this device without having water inside the water container Filling in water with water bucket Do NOT put your massager under faucet directly Be careful NOT to spill water onto the cover or control panel To save electricity or speed up water heating you can put in warm water but the warm water temperature should be less than 40 Celsius degrees Water Level refer to Figure 4 Wa...

Страница 11: ...rature reaches 40 C When its water temperature cools down below 40 C the Heating function will be turned on automatically again and so on When the water temperature reaches its default maximum temperature 40 C the Keep Warm indicator light on LCD display will be on Figure 1 Note the Heating function will not be on if your fill in water temperature is already higher than its default maximum 40 C Ch...

Страница 12: ...n on off massage function under P1 Figure 1 P1 Under P1 water temperature massage air bubble and ozone function can be chosen based on your need All buttons on the control panel are available for selection Under P1 if you do not change its default water temperature its water temperature will stay in between 35 C 95 F 40 C 104 F default setting P2 P3 P4 Preset spa programs Under P2 P3 P4 program ea...

Страница 13: ... but not to disconnect the power cord from wall outlet The Drainage button on control panel cannot be used before the Drainage Switch is switched down at the back of case Figure 2 Drainage step by step procedures Put a water bucket under the water drainage valve Figure 5 Switch down the Drainage Switch at the back of case Figure 2 The water drainage valve will open Figure 5 At this time the LCD sc...

Страница 14: ...terfall Switch to center position to have both waterfall and water jet function worked at the same time 14 Clean up Make sure your hands are not wet when unplugging power cord After each use before trying to clean up the container with dry towel always turn off power on control panel and unplug the power cord from wall outlet first Put power cord back to the storage compartment and have it closed ...

Страница 15: ... Massage is Off and vise versa Ozone Preset NOT working Time Minute Preset 50 minutes Mode P4 Preset all functions are NOT selectable except Heating Temp Temp Heating Temp Temp Preset maximum heating temperature 43 Celsius Massage Preset when water temperature reaches 39C Massage is On all the time until you turn it off Air Bubble Preset when water temperature reaches 39C Air Bubble is On for 2 mi...

Страница 16: ...time 3 minutes Default water temperature 35 C 95 F lowest to 40 C 104 F highest The highest heating temperature 48 C 117 F The lowest heating temperature 35 C 95 F With 110V 60Hz UL power cord Power consumption 800W KH298 Luxury water container big enough for any foot sizes Cleaning and Maintenance Before cleaning you must turn off the device and unplug the power cord from the electric outlet Make...

Страница 17: ...urn and collection systems or contact the retailer where the product was purchased They can take this product for environmental safe recycling Troubleshooting Problem Cause Solutions Water Jet or waterfall not working Water filter and or waterfall valve is blocked clean up the water filter if necessary Check and clean up the herbal bag basket Heating not working Heating function is turned off It m...

Страница 18: ... Turn off the device completely and let it cool down for a while before using it again P2 P3 P4 are present spa program Not allowed to change under preset spa programs P2 P3 P4 Massage not working under P2 P3 P4 Note This product is not intended to diagnose treat cure or prevent any disease Limited Warranty Please contact seller for warranty Limited warranty from manufacturer only for original pur...

Отзывы: