background image

Designed by & Manufactured for:

Bio-Medical Research Ltd., Parkmore Business Park West, Galway, Ireland.

Copyright: © 2007, Bio-Medical Research Ltd. All Rights Reserved 

Part No: 2400-5702   Rev.: 1   Date of Issue: 9/07

United Kingdom: 0845 070 77 77

Republic of Ireland: 1890 92 33 88

France: 0810 347 450

Deutschland: 0800 000 1094

España: 900994467

International: +353 1 844 1016

[email protected]

TBM IM:Layout 1  27/11/2007  14:15  Page 2

Содержание Total body Massager

Страница 1: ...2007 Bio Medical Research Ltd All Rights Reserved Part No 2400 5702 Rev 1 Date of Issue 9 07 United Kingdom 0845 070 77 77 Republic of Ireland 1890 92 33 88 France 0810 347 450 Deutschland 0800 000 1094 España 900994467 International 353 1 844 1016 info slendertone com TBM IM Layout 1 27 11 2007 14 15 Page 2 ...

Страница 2: ...ns SLENDERTONE TOTAL BODY MASSAGE UNIT Slendertone Total Body Massage has been designed for ease of use The function of each button on the control unit is explained below The unit emits a high tone for a valid key press and a low tone for an invalid key press 1 On Off Pause Button You must press and hold this button for 2 seconds to switch your unit on and off Pressing it briefly will pause unpaus...

Страница 3: ...low and helps speed up the removal of lactic acid as it accelerates the exchange between the blood supply and the muscle fibres As a result the muscles recover more quickly from fatigue becoming more relaxed with reduced stiffness Use programme 2 after intense exercise to promote recovery and relaxation Programme 3 Shiatsu Massage Shiatsu massage is used to stimulate the body s natural flow of ene...

Страница 4: ... at intensity 15 and increase as you get used to using Total Body Massage to a level that is comfortable for you English Fig b Fig a Fig c Fig d Fig f Fig e PAUSING A SESSION If you wish to pause a session at any point briefly press the On Off button and the stimulation will stop Briefly press the same button a second time to un pause the programme USING THE TRIGGER If you wish to vary the pre set...

Страница 5: ...om fortable contraction FRONT OF THIGHS BACK OF THIGHS CALF MUSCLES PAD PLACEMENT When placing the pads ALWAYS ensure that the two pads on one lead are used to massage the muscles on one side of your body and that the two pads from the second lead are used on the other side of your body See the photos below for pad pairings Men and women may use all pad positions Some of the positions below requir...

Страница 6: ...ity is high Pad contact symbol appears on the display Pads don t adhere to body Unpleasant feeling beneath the pads Error message E001 E002 E003 appears on the display POSSIBLE CAUSES Battery incorrectly inserted The battery is dead Lead s not fully inserted in sockets Intensity is too low The battery is low The battery is low Low quality batteries used Unit has been paused The batteries are low T...

Страница 7: ...r heart problem You are pregnant You suffer from cancer epilepsy or are under medical supervision for cognitive dysfunction The unit is in close proximity e g 1m to shortwave or microwave therapy equipment You are connected to high frequency surgical equipment Wearing the device necessitates placement over areas at which drugs medicines are administered by injection short term or long term e g hor...

Страница 8: ...orresponding with the LOT symbol Rated Outputs Voltage Currents Parameter 500Ω 1KΩ 1K5Ω Output RMSV 7 5V 12 5V 13 7V Output RMSA 14 9mA 12 5mA 9 2mA Output Frequency 2 99Hz 2 99Hz 2 99Hz DC Component Approx 0 C 0 C 0 C Positive Pulse Width 200 300µs 200 300µs 200 300 µs Negative Pulse Width 200 300µs 200 300µs 200 300 µs Interphase Interval 100 µs 100 µs 100 µs Attention This unit can deliver curr...

Отзывы: