2.3 Cartridge
assembly/replacement
Fig. 2.g
1.
Make sure that the water supply is shutoff and there is no residual
pressure;
2.
remove the fi lter cups using the spanner supplied;
3.
fi t the new cartridge as shown in the photo;
4.
reposition the cups correctly and tighten them using the spanner;
5.
open the water supply.
2.4 Membrane
assembly/replacement
Fig. 2.h
Fig. 2.i
Fig. 2.j
1.
Make sure that the water supply is shutoff and there is no residual
pressure;
2.
remove the hose from the connector and unscrew the vessel closing
cap;
3.
insert the membrane as illustrated in the photo to the side;
4.
make sure that the membrane is correctly in place and close the
vessel cap;
5.
reposition the hose and complete the “starting the fi rst time”
procedure (see paragraph 4.2).