22
ENG
“Wellness” +0300060EN - rel. 1.2 - 03.09.2012
installer
user
ser
vice
5.4 Keypad
6
4
5
3
2
1
Fig. 5.a
button
function
1
alarm
LED red lit: list active alarms
LED red Flashing: alarm list automatically covered
2
PRG
return to the “Main Menù” screen
from the “Main” screen access the main menu
3
ESC
return to the previous screen/display
4
UP
increase the set point
5
ENTER
from the “Rapid Selection” screen access an “Rapid Selection”
screens
from “Simple” screen: selection of type of essence
ENTER + PRG: move the mask “Simple” to “Main” (and vice
versa).
6
DOWN
decrease the set point
5.5 “Simple” screen
It is activated / deactivated by pressing PRG and ENTER simultaneously.
1
2
3
1
3
2
4
6
5
7
8
9
Fig. 5.b
symbol
function
1
day and month
2
set point temperature( can be modifi ed using the UP or
DOWN button)
3
temperature inside the steam (measured by the probe/
probes)
4
hour and minutes
5
time bands set
6
light on inside the steam bath
Essence ( e.g.
Mint )
essence enable (delivered when the humidifi er produces
steam)may be changed or disabled by pressing ENTER
All other buttons are disabled.
5.6 “Main” screen
1
2
3
4
5
8
6
7
Fig. 5.c
symbol
function
1
set point temperature( can be modifi ed using the UP or DOWN
button)
2 (*)
temperature inside the steam (measured by the probe/probes)
3
light on inside the steam bath
4
time bands set
5
steam production
6
supply fan on
7
exhaust fan on
8
when moving indicates the operation of the fans, when still
indicates fan enable but in stand-by
Essence
(e.g. Mint)
essence enable (delivered when the humidifi er produces steam)
The following screens can be accessed from the “Main” screen:
•
ENTER button: “Rapid Selection”
•
PRG button: “Main menu”.
(*) The temperature could alternate one of the following descriptions when:
•
ALARM BLOCKING
: steam disabled by alarm
•
OFF BY SUPERVISOR
: steam production disabled by supervisor;
•
OFF BY SCHEDULER:
steam production disabled during a pre-set
sheduler;
•
OFF BY REMOTO
: steam production interrupted through the opening
of the “Remote ON/OFF” contact;
•
OFF BY KEYBOARD
: steam disabled keyboard (see “Main” screen),
•
OFF MANUAL
: steam disabled from manual procedures in use (see
menu “Proced. Manuals).
5.7 “Rapid Selection” screen
Fig. 5.d
Rapid Selection
range
default note
Steam
ON/OFF
OFF
Essence*
1...3
If you select a number on
the left is the name given
to the essence
Fill essences ON/OFF
OFF
if ON you call the mask
below
Light *
ON/OFF/AUTO
OFF
Fan I
(supply fan)*
ON/OFF/AUTO
OFF
Fan E
(exhaust fan)*
ON/OFF/AUTO
OFF
Sanification* ON/OFF/AUTO
OFF
if ON you call the mask
below
*=appears only if enable from Installer Menù
NOTE: In AUTO mode, the light stays on until the last active time bands
while sanitation is activated after the last daily ON time slot.