115
ENG
General features and models
g0300122EN rel. 1.0 - 01.12.2021
18. GENERAL FEATURES AND MODELS
Models for indoor installation:
INDOOR models
UG045
UG090
UG150
UG180
UG300
rated supply voltage (Vac)
230V 50Hz (ver. UG***HD005) / 115V 60Hz (ver. UG***H1105)
steam connection (Ø mm)
1x80
1x80
1x80
2x80
2x80
steam outlet pressure limits (Pa)
0-2000 (0-0.30 PSI)
Feedwater
connection
384 G
temperature limits °C (°F)
0-45 (32-113)
pressure limits (MPa)
0.1-0.8 (1-8 bars) (14.5-166 PSI)
fi ll water instant fl ow-rate (l/min)
18 (4.76 US gal/min)
Drain water
connection ø mm (in)
50 (1.97)
typical temperature °C (°F)
≤100 (212)
drain water instant fl ow-rate (l/min) (drain pump
only)
32 (8.45 US gal/min)
drain water instant fl ow-rate (with drain temper-
ing)
44 l/min (T<60°C) (11.62 US gal/min)
operating conditions
0 to 45°C (32 to 113°F); 10-90% rH non cond.
storage conditions
-10 to 70°C (14 to 158°F), 5-95% rH
protection rating
IP20
auxiliary voltage / frequency (V - Hz)
24 / 50-60
instant steam production (kg/h / lbs/h)
(1)
45 (100)
90 (200)
150 (330)
180 (400)
300 (660)
power consumption at rated voltage (W)
187
255
309
389
500
Tab. 18.b
(1)
average steam production is aff ected by factors, such as: ambient temperature, water quality, steam distribution system.
Models for outdoor installation:
OUTDOOR models
UG045
UG090
UG150
UG180
UG300
UG450
rated supply voltage (Vac)
230V 50 Hz (ver. UG***YD005) / 115V 60 Hz (version UG***X1105)
steam connection (Ø mm)
1x80
1x80
1x80
2x80
2x80
3x80
steam outlet pressure limits Pa (PSI)
0-2000 (0-0.30 PSI)
Feedwater
connection
3/4 NPT
temperature limits °C (°F)
0-45 (32-113)
pressure limits (MPa)
0.1-0.8 (1-8 bars) (14.5-166 PSI)
fi ll water instant fl ow-rate (l/min)
18 (4.76 US gal/min)
Drain water
connection ø mm (in)
50 (1.97)
typical temperature °C (°F)
≤100 (212)
drain water instant fl ow-rate (l/min)
32 (8.45 US gal/min)
operating conditions
UG***X1105 (UL version)
-40 to 45°C (-40 to 113°F); 10-90% rH non-cond.
UG***YD005 (CE version)
(2)
0 to 45°C (32 to 113°F); 10-90% rH non cond.
storage conditions
-10 to 70°C (14 to 158°F), 5-95% rH
protection rating
outdoor IAS 12-94
auxiliary voltage / frequency (V - Hz)
24 / 50-60
instant steam production (kg/h / lbs/h)
(1)
45 (100)
90 (200)
150 (330)
180 (400)
300 (660)
450 (990)
power consumption at rated voltage W
UG***X1105 (UL version)
2248
2312
2368
2509
2619
4927
UG***YD005 (CE version)
(2)
248
315
368
509
619
927
Tab. 18.c
(1)
average steam production is aff ected by factors, such as: ambient temperature, water quality, steam distribution system.
(2)
-25 to 45°C (-13 to 113 °F); 10-90% rH non-cond. optional 1 x 1000 W heater
-40 to 45°C (-40 to 113 °F); 10-90% rH non cond. optional 2 x 1000 W heaters
Controller specifi cations:
type
c.pHC
auxiliary voltage / frequency (V - Hz)
24 / 50-60
maximum auxiliary power (VA)
90
probe inputs (general specifi cations)
can be selected for these signals: 0 to 1 Vdc, 0 to 10 Vdc, 2 to 10 Vdc, 0 to 20 mA, 4
to 20 mA
input impedance: 60 kΩ with signals: 0 to 1 Vdc, 0 to 10 Vdc, 2 to 10 Vdc
50 Ω with signals: 0 to 20 mA, 4 to 20 mA
power supply for active probes (general specifi cations)
24 Vdc (24 Vac rectifi ed), Imax= 250 mA
12 Vdc 5%, Imax= 50 mA
alarm relay outputs (general specifi cations)
250 V 2 A (2 A)
type of micro-switching action 1C
remote enabling input (general specifi cations)
voltage-free contact; max. resistance 50 Ω; Vmax = 24 Vdc; Imax = 5 mA
serial communication
three-wire RS485 / Fieldbus / BMS
USB port
USB type A
Ethernet port
Ethernet
Tab. 18.d