Carefree of Colorado Service
Manual
M
IRAGE
2-S
TAGE
052588-301r4
11
D
IAGNOSTICS
C
OMMON
O
PERATION
I
TEMS
The following items are operational items that may come up as questions during normal operation. These are
also given in the operator's manual.
1. If the optional Carefree EL ignition lockout is installed the system will disable the extend function while
the vehicle ignition key is in the ON position.
1.1. Special order RTL ignition lockouts will fully retract the awning(s) and disable the extend function.
1.2. Functions will return to normal operation when the ignition key is turned OFF.
1.3. Coach manufacturers may install their own lockout design. Refer to the coach literature for AC
power for accessories.
2. Direct Response Controls:
2.1. When 110VAC power is removed from the system, the controller
DOES NOT
retain previous
positioning information. When power is restored, positioning information is updated when the first
function is initiated.
2.2. The function LEDs (extend, retract and stop) perform a dual function. When the button is pressed, the
LED illuminates. The LED stays illuminated during the selected operation and after the awning has fully
extended or retracted. This provides an indicator of the awning position. When the stop button is
pressed, the LED will illuminate and stay on until a function is pressed. If on, it indicates that the awning
is partially extended/retracted.
2.3. All function buttons are press ON/press OFF. The auto-functions will continue until the awning is
fully extended/retracted or when the stop button is pressed.
3. Each awning has an independent motion sensor. During windy conditions, the awnings may not retract
concurrently.
4. For multiple awning installations: Pressing multiple buttons at the same time may cause the awnings to
appear to move erratically. If this occurs, press the stop button. Use the individual controls to set the
awning(s) to the desired position.
5. When 110VAC power is removed from the system, the controller
DOES NOT
retain previous positioning
information. When power is restored, positioning information is updated when the first function is
initiated.