Part number 3C4480 R10
9
May 2005
Controller 3000
PA
Group (x4)
PB1 and PA1... to... PB4 and PA4
4 3 2 1
2 1
PB
Prox Plus Mifare
Reader 1
Prox Plus Mifare
Reader 2
Note:
Within each group, you cannot mix Cardax IV readers with
Wiegand Readers. This is because connecting one Wiegand reader
requires all four pins on plug PB. For example, if you connect a
Prox Plus Mifare reader to Port 1 of Group 1, Port 2 of Group 1 can
only connect to another Cardax IV reader.
The terminating resistors (J1 for Group 1, J2 for Group 2, etc.) must
NOT be fitted for those groups to which Prox Plus Mifare readers
are connected.
Connecting to the Cardax FT Reader I/O Interface
The Cardax FT Reader I/O Interface has connections for up to
sixteen Prox Plus Mifare readers or other Cardax IV readers.
The Prox Plus Mifare reader connects to either plug PA or PB in
Groups 1 to 8.
Make the connections from the Prox Plus Mifare reader to the
Reader I/O interface as shown: