IMPORTANT SAFETY INSTRUCTIONS FOR INSTALLATION

WARNING – INCORRECT INSTALLATION CAN LEAD TO SEVERE INJURY 
FOLLOW ALL INSTALLATION INSTRUCTIONS CAREFULLY

Before installing the operator check that the door is in good mechanical condition, 
and correctly balanced, and that it opens and closes properly.

Do not use the force adjustments to compensate for a binding or sticking garage door.
Excessive force will interfere with the proper operation of the Safety Reverse System 
or damage the garage door.

Do not wear rings, watches or loose clothing while installing or servicing a garage
door operator.

To avoid serious personal injury from entanglement, 

remove any ropes

connected to 

the garage door before installing the door operator.

Install the remote mounted bell push button within sight of the door but away from 
any moving parts and at a height of at least 1.5 metres.

The safety reverse system

test is very important. The garage door must reverse when

obstructed on closing. 

Failure to properly adjust the operator may

result in serious

personal injury from a closing garage door. Repeat the test once a month and make 
any needed adjustments (see Advanced Settings 

<

, Menu 

b

and Menu 

c

on page

20 of this manual).

Installation and wiring must be in compliance with your local building and electrical codes. 

If the garage has no service entrance door then an exterior release kit MUST be fitted. 
This accessory allows manual operation of the garage door from outside in case of 
power failure. 

Disconnect electric power to the garage door operator before making repairs or 
removing covers.

Use the manual release lever to disengage the motor drive ONLY when the drive is 
switched OFF and, if possible, when the door is fully closed.

Examine the installation, in particular the cables, spring and mountings, for signs of
wear, damage or imbalance. Do not use if repair or adjustment is needed since a fault 
in the installation or an incorrectly balanced door may cause injury.

IMPORTANT SAFETY NOTE
Only operate the door when the door is in full view, free of obstacles with no persons 
(particularly children) near the door. Nobody should be allowed to enter or leave the 
garage whilst the door is in motion.

Page 2

Copyright:

No part of this manual may be reproduced without prior approval.
Subject to alterations in the interests of technical progress.

Содержание DC650NII

Страница 1: ...II DC 650NII DC 650NII DC 650NII DC 650NII DC 650NII DC 650NII DC 650NII DC 650NII DC 650NII DC 650NII DC 650NII DC 650NII DC 650NII DC 650NII DC 650NII DC 650NII DC 650NII DC 650NII DC 650NII DC 650N...

Страница 2: ...g garage door Repeat the test once a month and make any needed adjustments see Advanced Settings Menu b and Menu c on page 20 of this manual Installation and wiring must be in compliance with your loc...

Страница 3: ...sure maximum quality and safety In order to prevent damage to the garage door or garage door operator and to comply with the Machinery Directive it is important that this operator is fitted in accorda...

Страница 4: ...lly reverse if the door is not fully closed within 88 seconds Safety Stop Opening door will immediately stop when obstructed by person or object Beam Break For additional safety we recommend a Beam Br...

Страница 5: ...the screws are tightly fastened N B Use 4 large Phillips HD selftap screws provided Lens cover should face rear of garage 2 Fit the red slider that re engages the emergency release and operator pull...

Страница 6: ...age quick release a Pull cord a to disengage Carriage re engage remain disengaged See fig 3 b Move red slider b in direction of arrow to re engage carriage at next movement Start operator See fig 4 fi...

Страница 7: ...or GRP doors only and the upper holes for all other doors Level and mount operator Disengage carriage from chain or belt Door may only be moved with moderate speed Connect operator pull bar to door br...

Страница 8: ...etween highest travel point of door and rail Level and mount operator Disengage carriage from chain or belt Door may only be moved with moderate speed Connect operator pull bar to door bracket Note Re...

Страница 9: ...TOR CONTROL PANEL INDICATIONS Your automatic door operator is provided with an easy to read LED display panel with 4 light icons and three program buttons Light icons 2 door fully open 4 door fully cl...

Страница 10: ...te control in the Basic settings Changes in the extended programming level may only be carried out by specialists Advice To determine the error number add the figures of the irregularly flashing LED s...

Страница 11: ...he door electrically once to open or close position Advice All menus can be reset by a RESET function to the original values set by factory Reset is activated by pressing and together for more than 30...

Страница 12: ...e the OPEN and CLOSE buttons Advice The reference point has to be passed 1x Z will light up briefly when reference point has to be passed 1x Advice The reference point has to be passed 1x Z will light...

Страница 13: ...operator is now in operational normal mode I MAKING ADJUSTMENTS To change the settings of an individual menu 1 Press for approximately 2 seconds until LED blinks 2 Repeatedly press until desired indic...

Страница 14: ...Step 3 Actuate the desired button of the new hand transmitter and hold the button of the existing hand transmitter After 1 2 sec the LED on the new transmitter is glowing permanently Programming is te...

Страница 15: ...elt drive boom it is not possible to reinstall a limit cam Motorhead side Reference point clip should be 960 mm 30 mm from motorhead side Carriage Door side Chain clip can be manually connected Belt c...

Страница 16: ...ternal relay optional 2 external relay optional W20 Receiver HF module output 24V 24 VDC 50mA max 0V masse ground RC Contact bk black bn brown or orange rd red gr green bl blue ye yellow Wall control...

Страница 17: ...response on impulse Error 10 Temporarily isolate cabled key switches or interior push buttons from control unit Remove plug insert plug and look for cable fault Connecting terminals for IMPULSE butto...

Страница 18: ...nsitivity of power limit 8 K H S Learned power limit 8 K H S Power limit self monitoring unit 8 K H S Voltage monitoring is active 7 K H Photocell self monitoring unit not o k 7 K H Excess travel stop...

Страница 19: ...he 2nd programming level A setting should always be carried out as soon as a less sensitive setting has to be chosen due to door travel properties caused by site conditions as otherwise the automatic...

Страница 20: ...s set automatically Only change it if necessary error No 5 When increasing the set value the max force in OPEN direction is increased and thus the sensitivity of the automatic cut out is reduced Atten...

Страница 21: ...lues may be necessary 1 LED F and LED H blink and all others are illuminated 2 By pressing and set the desired maximum closing force Each illuminated LED represents 1 8 of the maximum total force 3 On...

Страница 22: ...u e SET START UP PHASE 8 1 Make sure LED K is blinking and all other are illuminated 2 Use or to change start up warning phase a No start up warning b 2 second start up warning with external signal re...

Страница 23: ...ss to store and to finish setting up the operator speed and level 2 settings The LEDs will automatically turn off starting at LED 8 and ending at LED 2 Operator is now in operational normal mode recog...

Страница 24: ...Tel 01280 703022 Fax 01280 702195 MAIN UK EIRE DISTRIBUTOR DC 650N II Garage Door Operator Connected loads 230 V 200 W in operation with lighting 3 9 W out of operation without lighting Door travel sp...

Страница 25: ...r 2 sec until LED X blinks and all others are illuminated h g j h g j j I Q U S Z E T R I Q U W Z E T F I Q J W H E T R 8 Q 7 W 6 E 5 4 I 1 7 2 6 3 5 4 Menu 2 Programming door closed position Menu 1 P...

Страница 26: ...4 8 Q 7 W 6 C 5 F 8 Q 7 W 6 C 5 4 8 Q 7 W 6 C 5 F 8 Q 7 W 6 C 5 4 8 Q 7 W 6 C 5 F I Q U X Z E T R I A U S Z E T R I Q U S H E T R I Q U W H E T F I Q U W H E T R K Q J W Z E T R 8 Q 7 W 6 E 5 4 I 1 7...

Страница 27: ...ction arm and appropriate safety devices etc and not until the complete installation has been declared to be in conformity with the provisions of the Machinery Directive The technical files for the op...

Страница 28: ...oor and that any safety devices provided are sui table for the application and are all working satisfactorily This will permit the nominated person to attach a CE label identifying the name of the ins...

Отзывы: