8.1
Fuses
F1-F3: Refer to the circuit diagrams.
F1
Internal
supply
fuses
Fitted if supply cable fitted.
Fitted on board to some types of EMC filter.
on-board and up to 16 Amps:
32mm x 6mm type F
other: GEC Safeclip
F2
Auxiliary
circuit
fuses
Fitted on board to some types of EMC filter.
May be omitted up to 25Amp/phase supply
rating.
2 Amps glass type F
On board: 20mm x 5mm
Other: 32mm x 6mm
F3
Heat
Light
fuses
May be omitted up to 25 Amp/phase supply
rating.
2 Amps glass type F
32mm x 6mm
Customer
fuses
Required if no supply cable fitted.
Recommended if cable fitted.
See rating label for amperage;
see table below for fuse rating.
Model Phases Volts
Supply
Fuse
Rating
Volts Supply
Fuse
Rating
CWF -/5
1-phase
220-240
10A
110-120
20A
CWF -/5
1-phase
208
12.5A
CWF -/13
1-phase
220-240
12.5A
110 / 120
25A / 32A
CWF -/13
1-phase
208
16A
CWF -/23
1-phase
220-240
30-32A
CWF -/23
1-phase
208
40A
208 delta
25A/ph
CWF -/23
3-phase
380/220 - 415/240
12.5A/ph
220-240 delta
20A
RWF -/5
1-phase
220-240
12.5A
110-120
25A
RWF -/5
1-phase
208
16A
RWF -/13
1-phase
220-240
25A
110-120
50A
RWF -/13
1-phase
208
25A
RWF -/13
2-phase+N
380/220 - 415/240
12.5A/ph
RWF -/23
1-phase
220-240
40A
RWF -/23
1-phase
208
50A
208 delta
25A/ph
RWF -/23
3-phase
380/220 - 415/240
12.5A/ph
220-240 delta
25A/ph
BWF range - same as CWF
8.2 Power Settings
The settings of the power limit parameter
OP.Hi
are as follows.
model
volts:
200
208
220, 280 230, 400 240, 415 254, 440
CWF 11/23, 12/23, 13/23
100
100
100
100
94
83
all
other
models
100 100 100 100 100 89
9.0
MF02
15