4 Troubleshooting
The tests and procedures stated in the table below facilitate diagnosing the
causes of the most frequent troubles and ease self-remedy where appropriate.
Possible cause
Solution
The welding machine cannot be started
Mains fuses
Check fuses, and replace, if necessary.
Residual current circuit breaker or internal
miniature circuit-breakers have tripped.
Switch on residual current circuit breaker or
internal miniature circuit-breakers (located
behind the cover plate).
No mains voltage
Check
Defective power switch
Replace, if necessary.
Machine stops during welding operation and
the LED “Error” on the top right of the
control panel lights up.
Thermal overload resulting from duty cycle
overrange.
Let cool down the power source.
Power source OFF/ON
Error in the cooling circuit, failure of fans.
Check cooling circuit, pump, fan, cooling
liquid level, hose connections.
Switch power source OFF/ON
Power section error.
Switch power source OFF/ON
Delivered compressed air is not sufficient.
Check compressed air supply, pressure
adjusted at the pressure reducer
≥
3 bars,
hose connections
Switch power source OFF/ON
Mains fuse is triggered during welding
Wrong mains fuses.
Clean the metal from any rust, color etc.
To confirm the message, press any key to
return to the chosen program/welding. (The
message locks the system function).
Duty cycle is exceeded.
Enter rated current of the existing mains
fuses in the BREAK program segment
Wrong fuse selection in the program segment
BREAK or cancel fuse function.
Enter measured current of the existing mains
fuses in the program segment BREAK or
select fuse function.
Cooling unit is not running, no indication on
the display
Internal miniature circuit breakers have tripped
Check miniature circuit breakers and switch
them on, if necessary
Pump is blocked or defective.
Check
Defective control.
Replace
Gun does not close after user has pressed
the start pushbutton.
No or insufficient compressed air supply.
Check compressed air supply and hose
connections
The electromagnetic valve is defective or does
not switch.
Check mains fuses