32/33
7.10.
Unstable temperatures inside the cabinet.
The unstable temperature is caused by the evaporator fans cease, and it can be check by the below
method: When the compressor is running, the light “Run” is on, the fan should be running, if the fan
stop, check the whether is any fault in the fan or fan connection. If the fan is broken, replace it with
the fan of the same model .
(→6.1.4)
7.11.
The digital display’s fault
This malfunction is caused by the display panel’s default, replace with the same model’s display
panel.
(→6.2.1)
7.12 Door switch fault.
1 >
.
Check if the X1 well connected
(
Fig.16
)
, if it ok, replace the switch please.
2 >
.
Remove the switch box fixing screws, and cut the switch.
(
Fig.19& Fig.19.1)
;
3 >. Peel off the scarfskin on the end about 12mm, cut the spare switch and peel off the scarfskin,
connect the ends and wrap the ends with insulating tape.
(Fig.20& Fig.20.1)