3/33
This symbol means the
instance forbidden
Danger
·Please make sure to discharge the rest refrigerant in the parts.
·When discharging refrigerant, make sure that it never go to the fire place and drain
to outdoors.
Tell the customers that they never close to the discharge place and the fire is
forbidden.
·Take apart the pipe by cutter.
Never take apart the part by soldering, otherwise it will fire the rest refrigerant in the
systems and cause blast.
·Exhaust the rest refrigerant in the systems before welding.
·After filling the refrigerant the sealing should be done by using smithing welding
nozzle.
Using the welding machine will fire the refrigerant and blast.
·Since the R600a is heavier than the air, please let the R600a on the ground go
especially for the hypogeum.
·The operation on the servicing refrigerant bottle should be done in place without fire
and outdoors.
·Use the refrigerant warner please, as the rest refrigerant will cause the fire.
·Don’t use fire in the place with rest refrigerant.
·Don’t place the default compressor in indoor.
Содержание WC6216
Страница 1: ...WC6216 Caple 60cm in column wine cabinet Technical information ...
Страница 2: ......
Страница 5: ......
Страница 12: ...7 33 3 Cooling system diagram ...
Страница 30: ...25 33 Diagram of main PCB connection Fig 16 Fig 15 Main PCB Four barbs fixing PCB ...