OM-CKPF/3 15
The
MAINTENANCE
Display is Password Protected. The Default Password is 100. When the
MAINT
button on the Navigation Pop-up display is pressed a keypad will be displayed to enter
the correct password. Once the correct password is entered the MAINTENANCE display is
accessed.
When the
MAINTENANCE
Display is accessed the user will have the option to set the clock
and date, turn Temp Assurance option on or off, set the Temp Assurance Low Temp Set Point,
adjust the Product pump
ON
delay or Navigate to the password protected
CAL
Display.
Set the Date and Clock
To set the date and clock press each number and enter a value on the keypad that will pop-up.
Once all the fields have a number press the Set
DATE/TIME
Button. This will change the Date
and Time only when all the fields have a number.
Set the Pump ON Delay
To set the Pump
ON
delay press on the Numeric Graphic and enter the amount of time after the
Product Valve Opens before the Pump begins. Default is 0.50 sec. This is set in Hundredths of a
second.
Turn On/Off Temperature Assurance
To turn on or off Temp Assurance simply press the
ON
or
OFF
button. When Temp Assurance
is turned ON the Low Temp Set point appears. Enter the desired Low Temperature Setting by
pressing on the numeric graphic and entering the set point in the pop-up keypad.
MAINT DISPLAY
Operation
Содержание CKPF/3
Страница 23: ...OM CKPF 3 23 Maintenance PRODUCT VALVE OPERATOR FOOT SWITCH INVERTER PUMP MOTOR ...
Страница 27: ...OM CKPF 3 27 Suggested Spare Parts List ...
Страница 28: ...28 OM CKPF 3 Suggested Spare Parts List ...
Страница 29: ...OM CKPF 3 29 Suggested Spare Parts List ...
Страница 30: ...30 OM CKPF 3 Wiring Schematic ...