The following 

COMMAND

 table describes the available commands:  

Flash count

 

Command

 

Description

 

1 flash 

STATUS 

Shows the device STATUS. As answer the led perform a flash sequence as reported 

in the “STATUS” table. 

If the device is performing the TEST (

refer to TEST command

this command stops it.  

2 flashes 

TEST 

Enter in TEST mode and transmits status and measurements every 5 seconds. If 
the device is in STANDBY mode or it is out of radio range, this command forces the 
connection procedure to the WSN and the return to the operative mode. The TEST 
stops after 120 seconds. During TEST, the led continuously shows the STATUS to 
monitor the received radio signal quality. 

CAUTION: Measures acquired during 

TEST

 phase are NOT saved. 

3 flashes 

ENROLL 

Association  to  the  network:  must  be  used  when  the  device  has  not  yet  been 
included  in  a  network,  starts  the  entry  and  association  procedure  to  the 

basestation

 (

refer 

to “

WineCap System - User Manual R30

). 

4 flashes 
  
 
+ 4 flashes 

STANDBY 

Temporary device deactivation: the device is stopped. The sampling process and 
the radio are/is turned off losing the connection to the network. To reactivate, a 
TEST  command  is  necessary.  The  STANDBY  command  must  be  given  twice  to 
confirm it: at the first sequence the led flashes alternating RED and GREEN lights, 
waiting  for  the  second  confirm  sequence  within  15  seconds.  At  the  command 
execution the led flashes as the STANDBY status (

refer to 

WIRELESS MODE STATUS 

Table

). 

5 flashes 
 
 
+ 5 flashes 

FACTORY 

RESET 

The device performs the memory deleting procedure and goes in STOP status. All 
samples,  configuration  and  wireless  network  data  associated  are  LOST.  To 
reactivate the device a new association and configuration procedure is necessary 
(

ENROLL command

). Also in this case, the FACTORY RESET command must be given 

twice  to  confirm  it.  At  the  command  execution  the  led  flashes  as  the 

“PROBE/DATALOGGER  NOT  ASSOCIATED”  status 

refer  to  

WIRELESS  MODE  STATUS 

Table

). 

5 flashes 
 
 
+ 3 flashes 

LOGGER      

NO WSN 

As  the  previous  command  but  performs  only  the  WSN  deleting  procedure  and 
disassociate  from  the 

basestation

.  The  device  enters  in  LOGGER  STAND  ALONE 

mode: data are kept, and the sampling activity CONTINUES with previous setup. 
Command must be given with 2 sequences: 5 flashes and then 3 flashes. At the 
command  execution  wait  for  the  device  reboot.    At  the  STATUS  command, 

“LOGGER” will be the answer (

refer to 

STAND-ALONE MODE  STATUS Table

). A new 

association (

ENROLL command

) is possible to a new 

basestation

4.

 

Enrolling the device. 

Not necessary if performed in factory before delivery. 

Enroll the device to the network referring to the 

WineCap System - User Manual R30

. In case the 

device is already enrolled but in 

STANDBY

 status, a 

TEST

 command must be issued (

refer t

Picture 4 - Commands table

).

 

5.

 

Installation procedure. 

After installing the 

basestation

 in appropriate place in charge, (

refer to 

WineCap System - User Manual R30

), be sure that the device is 

enrolled to the 

basestation

 and activated. 

Head for the environment to be monitored. On the way, to check the quality of the radio coverage, use the "

Field Measurer

" function. 

This function is activated issuing the 

TEST

 (

refer t

Picture 4 - Commands table

)command: position th

WineCapKey

 in the spot indicated 

in 

Picture  3  -  WineCapKey  positioning

  and  wait  for  two 

AMBER

  flashes,  then  remove  the 

WineCapKey

  from  device.  The  "

Field 

Measurer

" function lasts enabled for two minutes.  

To issue commands to the device, place the 

WineCapKey

 where indicated. 

Once the 

WineCapKey

 is detected, the led periodically emits 

AMBER

 flashes with a 2 second cadence.  

For each flash, a different command is associated; to confirm the command the 

WineCapKey

 must be removed from the sensible 

area immediately after the number of flashes corresponding at the desired command. The 

TEST

 corresponds to the second pulse and 

activate the "

Field

 

Measurer

" function.

 

 

Picture 4 - Commands table

 

Содержание WineCap WSD12-THEE

Страница 1: ...ected to the basestation that will be coupled with the device b USB Logger Mode For this operation mode stand alone with data downloads through USB the connection with the PC and the WineCapManager running on it is necessary in order to modify the device s operation mode The sampling interval must be set with the device in STAND ALONE refer to 6 Stand alone USB datalogger installation mode and aut...

Страница 2: ...al_R03 V4 8 3 Wireless device user interface The user interface consists of a virtual button that can be activated using the WineCapKey and of a two colors led To give a command user must approach the WineCapKey to the device s sensible area and keep it in that position the following picture Picture 3 WineCapKey positioning shows device s sensible points WineCapKey LED Picture 2 Device positioning...

Страница 3: ...sary ENROLL command Also in this case the FACTORY RESET command must be given twice to confirm it At the command execution the led flashes as the PROBE DATALOGGER NOT ASSOCIATED status refer to WIRELESS MODE STATUS Table 5 flashes 3 flashes LOGGER NO WSN As the previous command but performs only the WSN deleting procedure and disassociate from the basestation The device enters in LOGGER STAND ALON...

Страница 4: ... again when the device synchronizes with the WR12 repeater The link will not be reconfigured until completely lost by the device Because of this in some cases it could be necessary to force the operation In such cases put the device in STANDBY mode then run the TEST again refer to WineCap System User Manual R30 NOTE The display equipped datalogger WD04T is recommended to verify the signal quality ...

Страница 5: ...acquired 2 input channels Outdoor temperature Relative humidity Sampling interval Selectable from one minute to 24 hours 10 minutes default Datalogger capacity 128 000 samples for each channel Working temperature Operative 30 C 60 C Warehousing 40 C 70 C Radio frequency ISM 868MHz Radio coverage Up to 6Km in line of sight can be extended using WR12 battery powered repeaters Sealing IP65 Dimensions...

Страница 6: ...Strada Stratta 57 10090 CASTIGLIONE TORINESE TORINO ITALY VAT 04837130014 Phone 011 981 98 11 Fax 011 981 98 210 e mail info capetti it web www capetti it WA0154E_WSD12 THEE_User Manual_R03 V4 8 9 Mechanical dimensions Picture 7 Mechanical dimensions ...

Страница 7: ...011 65 CE that restricts the use of substances in the manufacturing of electronic devices The WEEE logo on the label indicates that this product is compliant with the WEEE EC Directive This symbol valid only in the European Union countries indicates that the product it is applied to MUST NOT be discarded with ordinary household or industrial waste but must be sent to an authorized reception point ...

Отзывы: