The device will give back the radio signal quality through led flashes: 

WIRELESS MODE STATUS

 Table 

Flash count - Wireless mode 

Status/Radio signal quality 

 

5 green flashes 

Excellent 

 

4 green flashes

 

Good

 

 

3 green flashes

 

Fair

 

 

2 amber flashes

 

Sufficient

 

 

1 red flash 

Insufficient 

 

1 red flash 2” long

 

OUT OF RANGE 

Network searching 

 

2 red flashes 2” long

 

STANDBY 

 

Short-long-short red 

flashes series  

FACTORY RESET 

Device not enrolled

 

Optimize reception selecting the best position: small movements can help. 

If the signal is absent or insufficient at the install point, 

WR12 repeater

 should be put between (

refer to 

WineCap System - User Manual 

R30

). Th

WR12 repeater

 

itself must be in a position where the signal level is at least sufficient. 

The network will reconfigure itself automatically; the signal will be good again when the device synchronizes with th

WR12 repeater

The link will not be reconfigured until completely lost by the device. Because of this, in some cases it could be necessary to force the 
operation. In such cases, put the device in 

STANDBY

 mode, then run the 

TEST

 again (

refer to “

WineCap System - User Manual R30

). 

NOTE

: The display equipped 

datalogger

 (

WD04T

) is recommended, to verify the signal quality during devices installation. 

6.

 

Stand-alone USB datalogger installation. 

Install the 

datalogger

 in appropriate place. 

If the sampling process has not yet been activated, you can start it through th

WineCapKey

 

Bring it closer to the sensitive point, wait for 2 flashes (

TEST

) (

refer t

Picture 4 - Commands table

and remove. The 

datalogger

 begins 

sampling according to your settings through your PC. 

Through th

WineCapKey

 is possible to ask for the status, bring it close to the 

datalogger

 for 1 flash (

STATE

) and remove it. 

STAND-ALONE MODE STATUS 

Table:  

Flash count - Stand-alone mode 

STATUS 

 

1 green flash 2 seconds long 

ACTIVE 

 

2 red flashes 2 seconds long 

STANDBY 

 

Sequence  of  red  flashes:  short,  2 
seconds long, short 

FACTORY RESET  

INVALID

 

datalogger

 clock! 

PC connection required 

 

 

 

Picture 5 - Status table - Radio signal quality

 

Picture 6 - Stand-alone datalogger status

 

Содержание WineCap WSD12-THEE

Страница 1: ...ected to the basestation that will be coupled with the device b USB Logger Mode For this operation mode stand alone with data downloads through USB the connection with the PC and the WineCapManager running on it is necessary in order to modify the device s operation mode The sampling interval must be set with the device in STAND ALONE refer to 6 Stand alone USB datalogger installation mode and aut...

Страница 2: ...al_R03 V4 8 3 Wireless device user interface The user interface consists of a virtual button that can be activated using the WineCapKey and of a two colors led To give a command user must approach the WineCapKey to the device s sensible area and keep it in that position the following picture Picture 3 WineCapKey positioning shows device s sensible points WineCapKey LED Picture 2 Device positioning...

Страница 3: ...sary ENROLL command Also in this case the FACTORY RESET command must be given twice to confirm it At the command execution the led flashes as the PROBE DATALOGGER NOT ASSOCIATED status refer to WIRELESS MODE STATUS Table 5 flashes 3 flashes LOGGER NO WSN As the previous command but performs only the WSN deleting procedure and disassociate from the basestation The device enters in LOGGER STAND ALON...

Страница 4: ... again when the device synchronizes with the WR12 repeater The link will not be reconfigured until completely lost by the device Because of this in some cases it could be necessary to force the operation In such cases put the device in STANDBY mode then run the TEST again refer to WineCap System User Manual R30 NOTE The display equipped datalogger WD04T is recommended to verify the signal quality ...

Страница 5: ...acquired 2 input channels Outdoor temperature Relative humidity Sampling interval Selectable from one minute to 24 hours 10 minutes default Datalogger capacity 128 000 samples for each channel Working temperature Operative 30 C 60 C Warehousing 40 C 70 C Radio frequency ISM 868MHz Radio coverage Up to 6Km in line of sight can be extended using WR12 battery powered repeaters Sealing IP65 Dimensions...

Страница 6: ...Strada Stratta 57 10090 CASTIGLIONE TORINESE TORINO ITALY VAT 04837130014 Phone 011 981 98 11 Fax 011 981 98 210 e mail info capetti it web www capetti it WA0154E_WSD12 THEE_User Manual_R03 V4 8 9 Mechanical dimensions Picture 7 Mechanical dimensions ...

Страница 7: ...011 65 CE that restricts the use of substances in the manufacturing of electronic devices The WEEE logo on the label indicates that this product is compliant with the WEEE EC Directive This symbol valid only in the European Union countries indicates that the product it is applied to MUST NOT be discarded with ordinary household or industrial waste but must be sent to an authorized reception point ...

Отзывы: