Caution – Equipment Damage (contd.)
-
As a general rule, mechanical force is permitted to act on the
flat-panel display only at the special fastening points (bore
holes, pins, angle brackets, straps).
-
The display’s normal mounting position is vertical. The angle of
inclination must not exceed 45°.
The flat-panel display complies with the electromagnetic immunity re-
quirements (EMC directive).
For optimum EMC immunity we recommend connecting the flat-panel
display to ground (enclosure) as an added measure. In most cases,
the electrical connection resulting from installation on supports (rails,
brackets) with good conduction properties is sufficient. Otherwise the
flat-panel display may additionally be connected to ground via the
special ground point.
EMC Caution
For optional touch version only!
Very strong electromagnetic fields may impair the accuracy of in-
tegrated touch screens. If the accuracy problems become perma-
nent, the display may have to be recalibrated.
Caution, Fire Hazard, Electric Shock Hazard
Device operators must be in a position to isolate devices that do
not have a power switch or whose power switch is not readily ac-
cessible from power at all times. This can be achieved by provid-
ing either a mains plug that is readily accessible or another dis-
connection device that is easily accessible.