background image

HZ 0 9 6 6 −E

Wide

Name of P art

roof  panel

round gutter

side frame

front frame

side frame

ar m

roof  retainer

roof  rafter

main frame

post

gutter

Cantaport

 made in Japan certified to AU standards 

RSC

 Series Installation

 

M

anual

   

Thank you very much for choosing our company's Cantaport products.

Please be sure to thoroughly read these instructions for assembling the Cantaport product in conjunction with the engineering 

details. DIY or Authorisied Cantaport installations must follow the manufactures assembling manual to avoid warranty cover. 

Please retain the manual for future reference and maintenance inspection. 

Содержание Assembly Instructions

Страница 1: ...allation Manual Thank you very much for choosing our company s Cantaport products Please be sure to thoroughly read these instructions for assembling the Cantaport product in conjunction with the engi...

Страница 2: ...below to prevent aluminum materials corrode sea sand cement enhancer water reducing cryopro tectant 1 Do not use sea sand for the foundation since it contains salt and may cause corrosion Do not use a...

Страница 3: ...imension Position of Posts and Base Dimension Dimension Position of Post Single D24 D27 D30 Wide D48 D54 D60 Length Dimension W Height Dimension H and Post Standard Position post could be changed as t...

Страница 4: ...elding wire net are arranged in concrete floor Dimension of projection which prevents floating at 4 rounds is more than 50mm 50mm Distance A from outside edge of base to around concrete floor is more...

Страница 5: ...shaped gutter 5 parts U shaped gutter 3 parts U shaped gutter 5 parts U shaped gutter 3 parts type Single Wide body size Depth D Length W standard post long post post main frame component parts type...

Страница 6: ...ts post cap post set R single post front frame side post gutter side post connecting parts post set L single post set L single hexagon bolt with washer spring washer M8 25 post front frame side post g...

Страница 7: ...be sure to return to the owner notice small truss screw 5 10 10 post ornament ornament bracket flat head screw 4 12 8 flat head screw 4 12 8 drilling screw 4 10 8 arm arm set wide arm hexagon nut M8...

Страница 8: ...main frame Right Left each 2 pcs Right Left each 2 pcs roof rafter set single gutter front frame set single gutter front frame set wide main frame set anchor rod arm hanging bracket arm holder back p...

Страница 9: ...frame cap single gutter cap single gutter cap wide arm cap side frame fixing bracket cap post ornament cap front frame cap wide content name quantity Parts ID shape content name quantity Parts ID shap...

Страница 10: ...polycarbonate mat panel When mark is CP it is the heat protection polycarbonate panel When mark is CF it is the heat protection FRP panel drilling screw elbow drain elbow saddle glue caution label sno...

Страница 11: ...ont frame Installation of the main frame Installation of the roof rafter Fixing the side frame Installation of the roof panels Installation of the roof retainer Attaching the round gutter parts post m...

Страница 12: ...of the connecting parts is upper side U shaped gutter U shaped up Fix the post fixing bracket with small truss screw 5 10 10 note note Fix the all hexagon bolts and fasten completely because this par...

Страница 13: ...post ornament cover Install the opposite side in the same way step2 Insert the post caps on the top and screw it with the flat head screw 4 12 8 drilling screw 4 10 8 post ornament set post set flat h...

Страница 14: ...the arm side The figure indicates right side step4 Insert the anchor rod into the post hole anchor step5 support stand plumb bob Insert post into the base hole and fix with support stand not to fall...

Страница 15: ...right left Install it as below figure The higher side is gutter side Fix the arm holder and the side frame fixing brackets as below front frame side front frame side gutter side gutter side note hexag...

Страница 16: ...side frame fixing bracket under has right left Install it as below figure Detailed figure of the silicon part indicates the silicon part hexagon bolt M10 25 parts box hexagon bolt M10 95 30 parts box...

Страница 17: ...side gutter side parts box small truss screw 5 10 10 parts box small truss screw 5 10 10 side frame side frame front frame side frame After connecting each frames with small truss screws as figure In...

Страница 18: ...Single Wide Single Wide Installation for Single is 3 screws For Wide is 4 screws 2 screws on top face and other 2 screws on down face step1 step2 Attach the roof panel cushions on the top side of all...

Страница 19: ...gonal dimension of roof Put the roof rafter into the front frame and screw it with driling screws 4 10 8 B part B part detail U shaped gutter U shaped gutter At A part screw it to guide hole At B part...

Страница 20: ...will run idle Holder part of the side frame after making 5 hole on the top face of the fin make 3 hole on the second fin Put the caps onto the side frame fixing bracket under After making 3 hole to th...

Страница 21: ...se the panel color may change by sunlight The panel width has two size when D24 30 48 54 60 the wider panel width 703mm put at both ends and the smaller one width 575mm put at midspan In only case of...

Страница 22: ...truss screw 4 10 7 parts set front frame cap silicon If the screws of retainer middle part tighten too much the screw will run idle tightening torque less than15kgf cm If the screw head leans when in...

Страница 23: ...of rain gutter Installation of gutter hole cap Detailed figure of the silicon part Be sure to do sealing work around screws in order to prevent danger when cleaning as well as for water proof silicon...

Страница 24: ...2018 RUSSELL WHITE 116216 0 RUW ISSUE FOR APPROVAL 11 10 18 CANTAPORT GROUND FLOOR BUILDING 2 630 MITCHAM ROAD MITCHAM VIC 3132 TEL 03 8872 6999 FAX 03 9873 2777 EMAIL melbourne structerre com au CAN...

Страница 25: ...GS TO SUIT EXPOSURE CLASSIFICATION f ALL WORK GENERALLY TO BUILDING CODE OF AUSTRALIA AND ALL RELEVANT BUILDING STANDARDS AND CODES g ALL SCREWS SIZES AS PER DETAILS COATING TO SUIT EXPOSURE CLASSIFIC...

Страница 26: ...ANTAPORT ARCHITECTURAL DRAWINGS FOR PURLIN TYPE DE5934 T5 56 5 22 1 5 T 1 5mm min 2 REFER TO CANTAPORT ARCHITECTURAL DRAWINGS FOR ARM TYPE DE5913 T5 60 T 3 5mm min REFER TO CANTAPORT ARCHITECTURAL DRA...

Страница 27: ...S 1 PINS MUST HIT REFUSAL ROCK OR EXTEND MIN 1200mm INTO NATURAL OCCURRING CLAY 2 MIN PIN LENGTH OF 2000mm 12x PINS REQUIRED MIN 3 HOLES MAY NEED TO BE PREDRILLED WHEN ENCOUNTERING ROCK REFER TO SUREF...