CANON SmartBase PC1210D/1230D/1270D REV. 1 MAR. 2002
7-9
CHAPTER 7 TROUBLESHOOTING
1.3.3 Adjusting the Mechanical Systems
1.3.3.1 Removing the Skew
Make a copy of the test sheet using the ADF in Direct, and make sure that the skew is as
indicated (T07-103-01). (See 1.2.2 of Chapter 7.)
Copy of the test sheet
a
b
(feeding direction)
F07-103-01
T07-103-01
1) Open the ADF.
2) Loosen the 3 screws [1], and move the left hinge up and down so that the skew will be
as indicated by referring to the index graduated at 1-mm intervals.
[1]
F07-103-02
b-a
Dimension (using A4)
0 ± 1.3 mm
Dimension (using LTR)
0 ± 1.3 mm
Содержание SmartBase 1270D
Страница 16: ......
Страница 18: ......
Страница 44: ......
Страница 46: ......
Страница 142: ......
Страница 143: ...COPYRIGHT 2002CANONINC 2000200020002000 CANONSmartBasePC1210D 1230D 1270DREV 1MAR 2002 CHAPTER 3 INSTALLATION...
Страница 144: ......
Страница 160: ......
Страница 161: ...COPYRIGHT 2002CANONINC 2000200020002000 CANONSmartBasePC1210D 1230D 1270DREV 1MAR 2002 CHAPTER 4 OPERATION...
Страница 162: ......
Страница 207: ...COPYRIGHT 2002CANONINC 2000200020002000 CANONSmartBasePC1210D 1230D 1270DREV 1MAR 2002 CHAPTER 5 MECHANICAL SYSTEM...
Страница 208: ......
Страница 278: ......
Страница 287: ...COPYRIGHT 2002CANONINC 2000200020002000 CANONSmartBasePC1210D 1230D 1270DREV 1MAR 2002 CHAPTER 7 TROUBLESHOOTING...
Страница 288: ......
Страница 396: ......
Страница 397: ...COPYRIGHT 2002CANONINC 2000200020002000 CANONSmartBasePC1210D 1230D 1270DREV 1MAR 2002 APPENDIX...
Страница 398: ......
Страница 402: ...APPENDIX A 4 COPYRIGHT 2002CANONINC 2000200020002000 CANONSmartBasePC1210D 1230D 1270DREV 1MAR 2002 Blank page...
Страница 406: ......