4) Remove the carriage cable holder from the front chassis. Remove 3 screws that fix the carriage rail to the main
chassis, then slowly put down the carriage rail.
5) Remove the carriage unit. Be cautious that the grease will not attach to any parts.
If the carriage unit is not necessary to be replaced, parts under the purge drive system unit, etc. can be
replaced without removing the carriage rail. While holding a set of a) main chassis, b) carriage rail, and c)
carriage unit together, just remove the screws from the left and right plates. This way, you just have to
reassemble the set of units (marking of the carriage rail position to the main chassis is not necessary).
30 / 54
Содержание PIXMA MP640
Страница 8: ...5 54 ...
Страница 9: ...6 54 ...
Страница 25: ...5 Remove the main case and sub case no screws 22 54 ...
Страница 26: ...23 54 ...
Страница 50: ...47 54 ...
Страница 54: ... 2 Service test print Service test print sample First page 51 54 ...
Страница 55: ... Second page 52 54 ...
Страница 56: ... 3 Ink absorber counter value print Print sample 4 5 Verification After Repair 53 54 ...