3. Adjusting the Position of the Blanking Exposure Lamp
1) Place the Test Sheet on the copyboard.
2) Select A4 copy paper.
3) Make a copy, and check that the left/right registration is correct.
4) Make a copy in Direct.
5) Check the image, and measure the non-image width shown in Figure 11-221.
Standard
(w/ standard frame erasing)
Table 11-202
Figure 11-221
6) If the non-image width is not as specified, turn the adjusting screw to adjust the
position of the blanking exposure lamp assembly.
Figure 11-222
Adjusting screw
A
A
10 mm
10 mm
(rear)
Mirror mount
COPYRIGHT © 1997 CANON INC. CANON NP6350/NP6251 REV. 0 JULY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 11 TROUBLESHOOTING
11-20
Paper
All sizes
Left/right non-image width (W1)
2.75 ± 2.5mm