The machine uses the six types of control shown in Tables 6-101 and -102 according
to how much time has passed since power-on and the environmental conditions.
l
60 Min from Power-On and Surface Temperature of Fixing Roller 75°C or Less
Table 6-101
l
60 Min or More from Power-On
Table 6-102
In addition, the following types of control exist for special conditions:
q
Power Saving Mode
The following operation takes place when the Pre-Heat key is pressed; power-saving
mode may be varied in user mode.
l
Control Temperature during Pre-Heat
*Period between another press on the Pre-Heat
key and the start of STBY.
Table 6-103
COPYRIGHT © 1997 CANON INC. CANON NP6350/NP6251 REV. 0 JULY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 6 FIXING SYSTEM
6-6
Mode
Internal
Control temperature
temperature
Standby
Copying
H mode
17°C or more
200°C
205°C
M mode
12° to 17°C
210°C
212°C
L mode
12°C or less
210°C
212°C
Mode
Internal
Control temperature
temperature
Standby
Copying
H mode
17°C or more
200°C
205°C
M mode
12° to 17°C
200°C
205°C
L mode
12°C or less
200°C
205°C
Saving rate
Control temperature*
Delivery
–10%
180°C
50 sec
–25%
155°C
90 sec
–50%
110°C
155 sec
None
195°C
0 sec
Содержание NP6251
Страница 231: ...COPYRIGHT 1997 CANON INC CANON NP6350 NP6251 REV 0 JULY 1997 PRINTED IN JAPAN IMPRIME AU JAPON 5 44 ...
Страница 806: ...COPYRIGHT 1997 CANON INC CANON NP6350 NP6251 REV 0 JULY 1997 PRINTED IN JAPAN IMPRIME AU JAPON A 6 ...
Страница 808: ...COPYRIGHT 1997 CANON INC CANON NP6350 NP6251 REV 0 JULY 1997 PRINTED IN JAPAN IMPRIME AU JAPON A 8 ...
Страница 812: ...PRINTED IN JAPAN IMPRIMÉ AU JAPON 0797S2 11 1 This publication is printed on 70 reprocessed paper ...