C. Checking the Operation
1) If you are not connecting a Remote Diagnostic Unit-A1 or a Copy Data iterface
Board-B1, i.e., if a Power Supply-A1 is not necessary, go to step 4).
Connect the connector of the Power Supply-A1 to the connector of the Copy Data
Controller-A1 as indicated.
(Make sure that the cord is in the groove of the board.)
Fig. 9-510
2) Connect the Power Supply-A1 to the power plug, and check that LED1 on the Copy
Data Controller-A1 turns on.
Fig. 9-511
1
6
SW4
SW1 ON
SW5 ON
LED6
LED5
LED4
LED3
LED2
LED1
SW2
SW3
JB2
JB1
JA1
JA2
EPROM
SRAM
CPU
IPC
JC9
JC6
JC5
JC8
J5
1
6
LED1
Connector on the Copy
Data Controller-A1
Connector of the
Power Supply-A1
Groove of the board
COPYRIGHT © 1997 CANON INC. CANON NP6350/NP6251 REV. 0 JULY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 9 INSTALLATION
9-46